False daptomycin-nonsusceptible MIC results by Microscan panel PC 29 relative to Etest results for Staphylococcus aureus and enterococci.
نویسندگان
چکیده
This study correlated the daptomycin MIC results obtained by Microscan and by Etest in Staphylococcus aureus and enterococci and found that the Microscan panel GP 29 had a high rate of false nonsusceptible results. Of the isolates interpreted as nonsusceptible by Microscan, 87% of Staphylococcus aureus, 90% of Enterococcus faecalis, and 88% of Enterococcus faecium isolates were interpreted as susceptible by Etest. In turn, Etest also has false nonsusceptible results compared to reference methods.
منابع مشابه
Accuracy of six antimicrobial susceptibility methods for testing linezolid against staphylococci and enterococci.
A challenge panel of enterococci (n = 50) and staphylococci (n = 50), including 17 and 15 isolates that were nonsusceptible to linezolid, respectively, were tested with the Clinical and Laboratory Standards Institute broth microdilution and disk diffusion reference methods. In addition, all 100 isolates were tested in parallel by Etest (AB Biodisk, Solna, Sweden), MicroScan WalkAway (Dade, West...
متن کاملCalcium-supplemented daptomycin Etest strips for susceptibility testing on Iso-Sensitest agar.
OBJECTIVE Iso-Sensitest agar (ISA), which is recommended by the BSAC for routine susceptibility testing of staphylococci and enterococci, contains insufficient calcium for testing daptomycin. Isotonic agar supplemented with 50 mg/L calcium has been advocated, but is not routinely available in many laboratories. We evaluated a daptomycin Etest that incorporates a constant level of calcium throug...
متن کاملMulticenter evaluation of the Etest and disk diffusion methods for differentiating daptomycin-susceptible from non-daptomycin-susceptible Staphylococcus aureus isolates.
Daptomycin is a novel cyclic lipopeptide that is approved by the U.S. Food and Drug Administration for the treatment of complicated skin and skin structure infections associated with Staphylococcus aureus and other gram-positive pathogens and also staphylococcal bacteremia, including right-sided endocarditis. The Clinical and Laboratory Standards Institute (CLSI) established "susceptible-only" ...
متن کاملPerformance of Vitek 2 for antimicrobial susceptibility testing of Staphylococcus spp. and Enterococcus spp.
Vitek 2 (bioMérieux, Inc., Durham, NC) is a widely used commercial antimicrobial susceptibility testing system. We compared MIC results obtained by Vitek 2 to those obtained by the Clinical and Laboratory Standards Institute (CLSI) broth microdilution (BMD) reference method for 134 staphylococcal and 84 enterococcal clinical isolates. Nineteen agents were evaluated, including all those availabl...
متن کاملPrecision of vancomycin and daptomycin MICs for methicillin-resistant Staphylococcus aureus and effect of subculture and storage.
The reproducibility of vancomycin and daptomycin MICs, measured by broth microdilution (BMD) and Etest, was prospectively assessed for 10 methicillin-resistant Staphylococcus aureus (MRSA) isolates from the blood samples from patients on vancomycin therapy. The isolates were tested at the time of isolation from blood and following 5, 10, and 20 subcultures and at 1, 3, 6, and 12 months of stora...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 51 1 شماره
صفحات -
تاریخ انتشار 2013