hemodynamic changes following endotracheal intubation in patients undergoing cesarean section with general anesthesia: application of glidescope® videolaryngoscope versus direct laryngoscope

نویسندگان

shahram amini department of anesthesiology and critical care, mashhad university of medical sciences, mashhad, iran; corresponding author: shahram amini, department of anesthesiology and critical care, mashhad university of medical sciences, mashhad, iran. tel: +98-5138640535, e-mail:

majid shakib buali hospital, artesh university of medical sciences, birjand, iran

چکیده

objectives the aim of this study was to compare hemodynamic changes following endotracheal intubation with gvl and mdl in patients undergoing cesarean section by general anesthesia. materials and methods seventy patients undergoing elective cesarean section by general anesthesia requiring endotracheal intubation were randomly allocated to be intubated with either gvl (n = 35) or mdl (n = 35). systolic, diastolic and mean arterial blood pressure (map), as well as pulse rates, and rate pressure product (rpp) were compared at baseline, after induction of anesthesia, and after intubation at one-minute interval for five minutes between the two groups. the patients were also compared for mallampati score, sore throat, intubation time and neonates’ apgar scores. results the patients were similar regarding systolic, diastolic and mean arterial blood pressure. pulse rate changes were significantly lower only at 1 and 3 minutes in the gvl group. the intubation times were 9.3 ± 1.4 and 10.6 ± 1.7 seconds in the mdl and gvl groups, respectively (p > 0.05). rpp was also lower in the gvl group at 1 and 2 minutes (p < 0.05) and returned to baseline afterwards. there was no significant difference between the groups for mallampati score, sore throat and apgar scores. conclusions our study revealed that hemodynamic parameters with gvl are only better preserved in the first three minutes after intubation in patients undergoing elective cesarean section and patients are similar regarding intubation time, sore throat and apgar score. background endotracheal intubation is usually associated with hemodynamic changes, especially in patients undergoing cesarean section by general anesthesia. glidescope® videolaryngoscope (gvl) is a novel video laryngoscope, which does not need direct exposure of vocal cords and produces lesser hemodynamic changes due to lower degrees of trauma and stimuli to oropharynx than the macintosh direct laryngoscope (mdl).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic Changes Following Endotracheal Intubation in Patients Undergoing Cesarean Section With General Anesthesia: Application of Glidescope® Videolaryngoscope Versus Direct Laryngoscope

BACKGROUND Endotracheal intubation is usually associated with hemodynamic changes, especially in patients undergoing cesarean section by general anesthesia. GlideScope® videolaryngoscope (GVL) is a novel video laryngoscope, which does not need direct exposure of vocal cords and produces lesser hemodynamic changes due to lower degrees of trauma and stimuli to oropharynx than the Macintosh direct...

متن کامل

Hemodynamic Changes Following Endotracheal Intubation With Glidescope® Video-Laryngoscope in Patients With Untreated Hypertension

BACKGROUND Tracheal intubation can be associated with considerable hemodynamic changes, particularly in patients with uncontrolled hypertension. The GlideScope(®) video-laryngoscope (GVL) is a novel video laryngoscope that does not need direct exposure of the vocal cords, and it can also produce lower hemodynamic changes due to lower degrees of trauma and stimuli to the oropharynx than a Macint...

متن کامل

Blood Glucose Alterations in Spinal versus General anesthesia in those undergoing Cesarean Section Delivery

Introduction: Major body injury or surgery is associated with reproducible metabolic and hormonal responses. Alteration of blood glucose levels is one of the necessary metabolic changes to surgical stress. Surgical techniques and different methods of anesthesia are factors that can help to control and balance the body’s hormones. One of the most effective ways for decline the endocrine-metaboli...

متن کامل

Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope.

BACKGROUND The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over the Macintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether ther...

متن کامل

Evaluation of Mexiletine Effect on Bispectral Index Changes and Hemodynamic Responses to Endotracheal Intubation and During General Anesthesia

  Background &Objective: Plaryngoscopy and tracheal intubation increase not only blood pressure and heart rate but also Bispectral Index (BIS) of the patients. In this study, hemodynamic and BIS changes were surveyed after tracheal intubation and during general anesthesia followed by mexiletine prescription . Materials & Methods: In this study, 50 patients aged between 20 and 60 who were ca...

متن کامل

COMPARISON OF HEMODYNAMIC CHANGES DUE TO INTRAVENOUS OXYTOCIN INFUSION DURING GENERAL AND SPINAL ANESTHESIA IN ELECTIVE CESAREAN SECTION

Background & Aims: Postpartum hemorrhage is one of the life-threatening complications after labor and cesarean section. Its prevalence is 6 percent. Metratonia is the most common cause of this complication. Some medications can prevent it. Oxytocin is the most common uterine vasoconstrictor and is used routinely after delivery for decreasing hemorrhage. The aim of this study is to compare hemod...

متن کامل