skin temperature over the carotid artery, an accurate non-invasive estimation of near core temperature

نویسندگان

farsad imani department of anesthesia, sina hospital, tehran university of medical sciences, tehran, iran

hamid reza karimi rouzbahani department of anesthesia, sina hospital, tehran university of medical sciences, tehran, iran

mehrdad goudarzi department of anesthesia, sina hospital, tehran university of medical sciences, tehran, iran

mohammad javad tarrahi department of epidemiology and biostatics, school of public health, lorestan university of medical sciences, khorramabad, iran

چکیده

conclusions the present study was the first research, in which rectum temperature was compared with that of skin over carotid artery, to find a safe location with easier access and higher accuracy for estimating near core body temperature. results obtained in this study showed that, using a model, it is possible to evaluate near core body temperature in children, by measuring skin temperature over carotid artery. results in the modeling group, the average rectum and carotid temperatures were 36.47 ± 0.54°c and 35.45 ± 0.62°c, respectively. the final model was obtained, as follows: carotid temperature × 0.561 + 16.583 = rectum temperature. the predicted value was calculated based on the regression model and then compared with the measured rectum value, which showed no significant difference (p = 0.361). patients and methods totally, 124 patients within the age range of 2 - 6 years, undergoing elective surgery, were selected. temperature of rectum and skin over the carotid artery was measured. then, the patients were randomly divided into two groups (each including 62 subjects), namely modeling (mg) and validation groups (vg). first, in the modeling group, the average temperature of the rectum and skin over the carotid artery were measured separately. the appropriate model was determined, according to the significance of the model’s coefficients. the obtained model was used to predict the rectum temperature in the second group (vg group). correlation of the predicted values with the real values (the measured rectum temperature) in the second group was investigated. also, the difference in the average values of these two groups was examined in terms of significance. background during anesthesia, continuous body temperature monitoring is essential, especially in children. anesthesia can increase the risk of loss of body temperature by three to four times. hypothermia in children results in increased morbidity and mortality. since the measurement points of the core body temperature are not easily accessible, near core sites, like rectum, are used. objectives the purpose of this study was to measure skin temperature over the carotid artery and compare it with the rectum temperature, in order to propose a model for accurate estimation of near core body temperature.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Skin Temperature Over the Carotid Artery, an Accurate Non-invasive Estimation of Near Core Temperature

BACKGROUND During anesthesia, continuous body temperature monitoring is essential, especially in children. Anesthesia can increase the risk of loss of body temperature by three to four times. Hypothermia in children results in increased morbidity and mortality. Since the measurement points of the core body temperature are not easily accessible, near core sites, like rectum, are used. OBJECTIV...

متن کامل

Non-invasive monitoring of brain temperature by near-infrared spectroscopy

Optical techniques are promising methods for measuring tissue temperature noninvasively due to the transparency of tissue to near infrared-light and the temperature dependent light-absorbing properties of endogenous absorbers, particularly water. Besides being noninvasive, the instruments are compact and portable, permitting bedside monitoring.

متن کامل

Non-invasive continuous core temperature measurement by zero heat flux.

Reliable continuous core temperature measurement is of major importance for monitoring patients. The zero heat flux method (ZHF) can potentially fulfil the requirements of non-invasiveness, reliability and short delay time that current measurement methods lack. The purpose of this study was to determine the performance of a new ZHF device on the forehead regarding these issues. Seven healthy su...

متن کامل

Thermistor recording of forehead skin temperature as an index of carotid artery disease.

Skin temperatures were recorded from the medial upper orbital area and above the nasal, mid and lateral portions of the brows in normal subjects and in patients with suspected cerebrovascular disease. Temperatures were reduced across the brow in patients with external carotid artery disease. Temperatures were lower than normal in the orbit in patients with internal carotid artery disease except...

متن کامل

Thermistor Recording of Forehead Skin Temperature as an Index of Carotid Artery Disease By MARGARET

Skin temperatures were recorded from the medial upper orbital area and above the nasal, mid and lateral portions of the brows in normal subjects and in patients with suspected cerebrovascular disease. Temperatures were reduced across the brow in patients with external carotid artery disease. Temperatures were lower than normal in the orbit in patients with internal carotid artery disease except...

متن کامل

Non-invasive Spatio-temporal Temperature Estimation Using Diagnostic Ultrasound

A method for non-invasively estimating tissue temperatures using 2D diagnostic ultrasound imaging arrays is presented in this paper. It is based on a linear relationship between the apparent speckle pattern displacements and temperature, as seen on acquired A-lines when the sample is heated by external heating elds. The proportionality constant between speckle displacement and temperature is de...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
anesthesiology and pain medicine

جلد ۶، شماره ۱، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023