validity of integrative weaning index of discontinuation from mechanical ventilation in iranian icus

نویسندگان

seyed jalal madani trauma research center, faculty of medicine, baqiyatallah university of medical sciences, tehran, ir iran; iranian society of anesthesiology and critical care, tehran, ir iran

masoud saghafinia trauma research center, faculty of medicine, baqiyatallah university of medical sciences, tehran, ir iran; iranian society of anesthesiology and critical care, tehran, ir iran

homeira sedighi nezhad trauma research center, faculty of nursing, baqiyatallah university of medical sciences, tehran, ir iran

abbas ebadi trauma research center, faculty of nursing, baqiyatallah university of medical sciences, tehran, ir iran

چکیده

results there were 80 successful and 44 unsuccessful as well as 72 successful and 8 unsuccessful weaning cases in the first and second phase of the study, respectively. the area under the roc curves for iwi was 0.967, with standard error of 0.020, 95% confidence interval of 0.899 to 0.993 and significance level of p = 0.001, se = 94.59, sp = 66.67, ppv = 97.22, npv = 50, da = 92.5 and likelihood ratio of positive test being 2.84 besides the lowest likelihood ratio of negative test equal to 0.08), with diagnostic odds ratio being 97% and confidence interval of 0.82 to 0.97. objectives this study is to determine the validity of integrative weaning index as a mechanical ventilation discontinuation predictor in patients hospitalized in the iranian intensive care units. patients and methods this scale was evaluated on 124 adult patients who were on mechanical ventilation for more than 24 hours, in two 24-hour phases, in six icus (surgery-trauma-medical-poisoning) of selected hospitals in tehran, totaling 60 beds, by the researcher as a single blind test. inclusion criteria were: patient 18 to 80 years old, none of them suffering from neurological and neuromuscular diseases, none or a minimal dose of sedative drugs being used (15 - 18 points based on palma and cook criteria), non-addict or heavy smokers, not admitted in icu-oh. the study was conducted from november 2011 to december 2012. the ventilators used were from rafael brand. background today, usage of weaning index is a controversial issue. proper use of these indexes is beneficial for prevention of the losses caused by weaning failure, rapid and reliable identification of patients who are potentially ready for spontaneous breathing and accelerating the weaning of mechanical ventilation. conclusions integrative weaning index has appropriate predictive validity for weaning patients from mechanical ventilation in iranian intensive care units.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new integrative weaning index of discontinuation from mechanical ventilation

INTRODUCTION Indexes predicting weaning outcome are frequently inaccurate. We developed a new integrative weaning index aimed at improving the accuracy of the traditional indexes. METHODS Three hundred and thirty-one patients mechanically-ventilated for more than 24 hours were evaluated. Initially, the threshold values of each index that best discriminate between a successful and an unsuccess...

متن کامل

Weaning from mechanical ventilation

D iscontinuation of ventilation is estimated to take up to 40% of the total duration of ventilatory support, and around 3–6% of patients admitted to the intensive care unit (ICU) require a prolonged course of mechanical ventilation (MV). Patients being liberated from ventilatory support therefore occupy a significantnumber of ICUbeds andhave a major impact on healthcare resources. There have be...

متن کامل

Weaning from mechanical ventilation.

Approximately 20% of all mechanically ventilated patients fail their first attempt to wean. Prolonged mechanical ventilation increases morbidity, mortality, and costs. No single weaning parameter predicts patient ability to wean. Weaning studies suggest that daily trials of spontaneous breathing for appropriate patients assured by standing protocol and driven by respiratory care practitioners a...

متن کامل

Weaning from mechanical ventilation.

An understanding of respiratory physiology is helpful when weaning a patient from mechanical ventilation. Various criteria are available that assess pulmonary function and the patient's ability to breathe spontaneously. The majority of patients are weaned without difficulty, but a small percentage will require careful evaluation. A complete assessment of the patient is essential during the wean...

متن کامل

Weaning from mechanical ventilation

INTRODUCTION This article reviews the literature on the weaning process in relation to nursing care. Weaning is defined as the process of gradually reducing mechanical ventilatory support as the patient’s own respiratory system recovers from disease (Keen, 2000). This process has been identified as one of the highest-ranked research priorities in nursing care by the American Association of Crit...

متن کامل

Weaning from mechanical ventilation

Practice guidelines on weaning should be based on the results of several well-designed randomized studies performed over the last decade. One of those studies demonstrated that immediate extubation after successful trials of spontaneous breathing expedites weaning and reduces the duration of mechanical ventilation as compared with a more gradual discontinuation of ventilatory support. Two other...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
thrita

جلد ۲، شماره ۴، صفحات ۶۲-۸

میزبانی شده توسط پلتفرم ابری doprax.com