the cell survival of f10b16 melanoma and 4t1 breast adenocarcinoma irradiated to gamma radiation using the mtt assay based on two different calculation methods

نویسندگان

s. nikzad ph.d. candidate, department of medical physics, faculty of medical sciences, tarbiat modares

b. hashemi associate professor, department of medical physics, faculty of medical sciences, tarbiat modares university, tehran, iran

m. h. zuhair professor, department of immunology, faculty of medical sciences, tarbiat modares university, tehran, iran

h. mozdarani professor, department of medical genetics, faculty of medical sciences, tarbiat modares university, tehran, iran

چکیده

background: various mtt assay methods are proposed to obtain the cell sur- vival parameters. objective: determining the survival curve characteristics of two cancerous cells of interest based on a common and a novel mtt assay method after exposing them to ionizing radiation. method: a common and a novel mtt assay method were used and compared for obtaining the f10b16 melanoma and 4t1 breast adenocarcinoma survivals after exposing them to ionizing radiation from a co-60 machine. to obtain the survival parameters of the cells based on the common method, the cells were inoculated in 96-well plates. after irradiating the plates, the mtt assay was performed over the following days for a period of 8 days. thereafter, the survival fraction was calcu- lated from a simple equation for every day from which the best day was selected. to acquire the cells’ survival parameters based on the novel method, extensive experi- ments were performed on a large number of samples. then, the mtt assay was done in every day following various experimental treatments to acquire the exponential growth. finally, the cells’ survivals were determined by measuring the space between relevant growing curves. results: at low doses (<4gy) the two mtt assay methods indicated the same re- sults. however, at higher doses there were significant differences among the findings. conclusion: both of the mtt methods indicated that the cells’ responses are de- pendent on the dose levels used. although the implementation of the common mtt assay method is simpler, the novel method seems to show more precise and reliable results at all levels of radiation doses.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Cell Survival of F10B16 Melanoma and 4T1 Breast Adenocarcinoma Irradiated to Gamma Radiation Using the MTT Assay Based on Two Different Calculation Methods

Background: Various MTT assay methods are proposed to obtain the cell sur- vival parameters.Objective: Determining the survival curve characteristics of two cancerous cells of interest based on a common and a novel MTT assay method after exposing them to ionizing radiation.Method: A common and a novel MTT assay method were used and compared for obtaining the F10B16 melanoma and 4T1 breast adeno...

متن کامل

The Cell Survival of F10B16 Melanoma and 4T1 Breast Adenocarcinoma Irradiated to Gamma Radiation Using the MTT Assay Based on Two Different Calculation Methods

BACKGROUND various MTT assay methods are proposed to obtain the cell survival parameters. OBJECTIVE determining the survival curve characteristics of two cancerous cells of interest based on a common and a novel MTT assay method after exposing them to ionizing radiation. METHODS a common and a novel MTT assay method were used and compared for obtaining the F10B16 melanoma and 4T1 breast ade...

متن کامل

The effect of delivering compensating doses on the survival of F10B16 melanoma and 4T1 breast adenocarcinoma treated with prolonged radiation delivery time

Background: Increasing the complexity in modern radiotherapy techniques have increased the delivery time lowering consequently the treatment efficacy. Through simulating the delivery time delay encountered in such techniques, its&rsquo; effect on two cancer cell lines and the compensating doses given to prevent such effect was investigated. Materials and Methods: F10B16 and 4T1 cancer cell line...

متن کامل

the effect of delivering compensating doses on the survival of f10b16 melanoma and 4t1 breast adenocarcinoma treated with prolonged radiation delivery time

background: increasing the complexity in modern radiotherapy techniques have increased the delivery time lowering consequently the treatment efficacy. through simulating the delivery time delay encountered in such techniques, its’ effect on two cancer cell lines and the compensating doses given to prevent such effect was investigated. materials and methods: f10b16 and 4t1 cancer cell lines were...

متن کامل

the evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine

abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...

15 صفحه اول

on the relationship between using discourse markers and the quality of expository and argumentative academic writing of iranian english majors

the aim of the present study was to investigate the frequency and the type of discourse markers used in the argumentative and expository writings of iranian efl learners and the differences between these text features in the two essay genres. the study also aimed at examining the influence of the use of discourse markers on the participants’ writing quality. to this end the discourse markers us...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of biomedical physics and engineering

جلد ۳، شماره ۲ Jun، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023