assessment of the radiation attenuation properties of several lead free composites by monte carlo simulation
نویسندگان
چکیده
background: in diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range. objective: although lead aprons have good radiation protection properties, in recent years, researchers have been looking for alternative materials to be used instead of lead apron because of some problems derived from lead-content of aprons. because of its lead-content, these radiation protection garments are so heavy and uncomfortable for the staff to wear, particularly in long-time uses. in addition, lead is a toxic element and its disposal is associated with environmental and human-health hazards. method: in this study, several new combinations of lead free materials ((w-si), (w-sn-ba-epvc), (w-sn-cd-epvc)) have been investigated in the energy range of diagnostic radiology in two geometries: narrow and broad beam. geometries of the radiation attenuation characteristics of these materials was assessed in 40, 60, 90 and 120 kvp and the results compared with those of some lead-containing materials ((pb-si), (pb-epvc)). results: lead shields still provide better protection in low energies (below 40 kvp). combination of w-sn-cd-epvc has shown the best radiation attenuation features in 60 and 90 kvp and the composition of (w-sn-ba-epvc) represents the best attenuation in 120 kvp, even better than previously mentioned lead- containing composites. conclusion: lead free shields are completely effective for protection against x-ray energies in the range of 60 to 120 kvp.
منابع مشابه
Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation
Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...
متن کاملAssessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation
BACKGROUND In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range. OBJECTIVE Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for alte...
متن کاملcontrol of the optical properties of nanoparticles by laser fields
در این پایان نامه، درهمتنیدگی بین یک سیستم نقطه کوانتومی دوگانه(مولکول نقطه کوانتومی) و میدان مورد مطالعه قرار گرفته است. از آنتروپی ون نیومن به عنوان ابزاری برای بررسی درهمتنیدگی بین اتم و میدان استفاده شده و تاثیر پارامترهای مختلف، نظیر تونل زنی(که توسط تغییر ولتاژ ایجاد می شود)، شدت میدان و نسبت دو گسیل خودبخودی بر رفتار درجه درهمتنیدگی سیستم بررسی شده اشت.با تغییر هر یک از این پارامترها، در...
15 صفحه اولMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
متن کاملassessment of the efficiency of s.p.g.c refineries using network dea
data envelopment analysis (dea) is a powerful tool for measuring relative efficiency of organizational units referred to as decision making units (dmus). in most cases dmus have network structures with internal linking activities. traditional dea models, however, consider dmus as black boxes with no regard to their linking activities and therefore do not provide decision makers with the reasons...
Monitoring and Risk Assessment of Lead and Cadmium in Milks from East of Iran Using Monte Carlo Simulation Method
Background and Objectives: Milk is an important component of the human diet. Exposure to heavy metals through dairy consumption of contaminated foods endangers human health. The aim of this study was to assess concentrations of lead and cadmium in raw milk samples from east of Iran and their safety risks. Materials and Methods: In this study, 54 raw milk samples from five regions were selected...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of biomedical physics and engineeringجلد ۵، شماره ۲ Jun، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023