evaluation of lung density and its dosimetric impact on lung cancer radiotherapy: a simulation study
نویسندگان
چکیده
background: the dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. therefore, it becomes necessary to quantify these deviations. objective: the present study has been undertaken to find out inter- and intra- lung density variations and its dosimetric impact on lung cancer radiotherapy using monte carlo code fluka and pbc algorithms. material and methods: density of 100 lungs was recorded from their ct images along with age. then, after pdd calculated by fluka mc code and pbc algorithm for virtual phantom having density 0.2 gm/cm3 and 0.4 gm/cm3 (density range obtained from ct images of 100 lungs) using co-60 10 x10 cm2 beams were compared. results: average left and right lung densities were 0.275±0.387 and 0.270±0.383 respectively. the deviation in pbc calculated pdd were (+)216%, (+91%), (+)45%, (+)26.88%, (+)14%, (-)1%, (+)2%, (-)0.4%, (-)1%, (+)1%, (+)4%, (+)4.5% for 0.4 gm/cm3 and (+)311%, (+)177%, (+)118%, (+)90.95%, (+)72.23%, (+)55.83% ,(+)38.85%, (+)28.80%, (+)21.79%, (+)15.95%, (+)1.67%, (-) 2.13%, (+)1.27%, (+)0.35%, (-)1.79%, (-)2.75% for 0.2 gm/cm3 density mediums at depths of 1mm, 2mm, 3mm, 4mm, 5mm, 6 mm, 7 mm, 8mm, 9mm,10mm, 15mm, 30mm, 40mm, 50mm, 80mm and 100 mm, respectively. conclusion: large variations in inter- and intra- lung density were recorded. pbc overestimated the dose at air/lung interface as well as inside lung. the results of monte carlo simulation can be used to assess the performance of other treatment planning systems used in lung cancer radiotherapy.
منابع مشابه
Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study
Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations.Objective: The present study has been undertaken to find out inter- and intra- lung density variations and its dosi...
متن کاملEvaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation
Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...
متن کاملA study on the esophageal cancer radiotherapy effects on the patient’s lung health
Introduction: Radiotherapy with or without surgery plays an important role in the treatment of patients with esophageal cancer. In the treatment planning of esophageal cancer, usually normal lung volume was observed in the treatment fields and probably received high radiation dose. The incidence of radiation pneumonitis (RP) after radiotherapy (RT) for sensitive organ of lu...
متن کاملImpact of 3D conformal radiotherapy on lung function of patients with lung cancer: a prospective study.
BACKGROUND The development of three-dimensional conformal radiotherapy (3D-RT) has enabled the restriction of the dose to normal lung, limiting radiation-induced lung injury. OBJECTIVES This study was designed to describe the time course of lung function until 7.5 months after 3D-RT in patients with lung cancer, and assess the relationship between lung function changes and dose-volume histogr...
متن کاملa study on rate making and required reserves determination in reinsurance market: a simulation
reinsurance is widely recognized as an important instrument in the capital management of an insurance company as well as its risk management tool. this thesis is intended to determine premium rates for different types of reinsurance policies. also, given the fact that the reinsurance coverage of every company depends upon its reserves, so different types of reserves and the method of their calc...
Evaluation of methods of co-segmentation on PET/CT images of lung tumor: simulation study
Introduction: Lung cancer is one of the most common causes of cancer-related deaths worldwide. Nowadays PET/CT plays an essential role in radiotherapy planning specially for lung tumors as it provides anatomical and functional information simultaneously that is effective in accurate tumor delineation. The optimal segmentation method has not been introduced yet, however several ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of biomedical physics and engineeringجلد ۲۰۱۲، شماره ۱۲، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023