estimation of photon specific absorbed fractions in digimouse voxel phantom using monte carlo simulation code fluka
نویسندگان
چکیده
background: most preclinical studies are carried out on mice. for internal dose assessment of a mouse, specific absorbed fraction (saf) values play an important role. in most studies, saf values are estimated using older standard human organ compositions and values for limited source target pairs. objective: saf values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 kev were evaluated for the digimouse voxel phantom incorporated in monte carlo code fluka. the organ sources considered in this study were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal, eye and brain. the considered target organs were lungs, skeleton, heart, bladder, testis, stomach, spleen, pancreas, liver, kidney, adrenal and brain. eye was considered as a target organ only for eye as a source organ. organ compositions and densities were adopted from international commission on radiological protection (icrp) publication number 110. results: evaluated organ masses and saf values are presented in tabular form. it is observed that saf values decrease with increasing the source-to-target distance. the saf value for self-irradiation decreases with increasing photon energy. the saf values are also found to be dependent on the mass of target in such a way that higher values are obtained for lower masses. the effect of composition is highest in case of target organ lungs where mass and estimated saf values are found to have larger differences. conclusion: these saf values are very important for absorbed dose calculation for various organs of a mouse.
منابع مشابه
Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...
متن کاملEstimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
BACKGROUND Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs. OBJECTIVE SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV we...
متن کاملEvaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA
Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...
متن کاملSpecific Absorbed Fractions of Internal Photon and Electron Emitters in a Human Voxel-based Phantom: A Monte Carlo Study
The specific absorbed fraction (SAF) of energy is an essential element of internal dose assessment. Here reported a set of SAFs calculated for selected organs of a human voxel-based phantom. The Monte Carlo transport code GATE version 6.1 was used to simulate monoenergetic photons and electrons with energies ranging from 10 keV to 2 MeV. The particles were emitted from three source organs: kidn...
متن کاملMonte Carlo calculation of specific absorbed fractions: variance reduction techniques.
The purpose of the present work is to calculate specific absorbed fractions using variance reduction techniques and assess the effectiveness of these techniques in improving the efficiency (i.e. reducing the statistical uncertainties) of simulation results in cases where the distance between the source and the target organs is large and/or the target organ is small. The variance reduction techn...
متن کاملEvaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code
Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide. Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of biomedical physics and engineeringجلد ۲۰۱۲، شماره ۱۲، صفحات ۰-۰