comparison of successful intubation with two different blades of laryngoscope: single-use and reusable.

نویسندگان

ali shahriari department of anesthesiology, zahedan university of medical sciences.

maryam khooshideh departement of obstetrics, zahedan university of medical siences.

hassan enayaty department of anesthesiology, zahedan university of medical sciences.

چکیده

background: many types of single-use blades are manufactured with different designs and materials. there have been several reports of difficulties in obtaining a view of the glottis with single-use laryngoscopes. the purpose of this prospective study was to compare the quickness and the success rate of endotracheal intubations with two different laryngoscope blades: disposable laryngoscope blades and reusable laryngoscope blades. methods: the study included 200 patients aged 18 to 70 who were admitted to the operating room of the ali ebne abitaleb hospital in zahedan. the patients were randomly divided in two groups. disposable laryngoscope blades were used for the first group and reusable laryngoscope blades were used for the second group. the endotracheal intubation duration and the failure rate of the intubation were assessed in the two groups. results: no failures and prolongations of intubations were found in the reusable laryngoscope blades group compared with 21% incidence of prolonged intubations and 14% incidence of failed intubations in the prolonged intubations group which led to change of the laryngoscope by the anesthetists (p<0.05). conclusions: the single-use laryngoscope blades appear to be efficient devices because they do not modify the ease of endotracheal intubation in most cases. nonetheless, for difficult intubations it is advised to maintain conventional laryngoscopes in reserve.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of plastic single-use and metal reusable laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia.

BACKGROUND Plastic single-use laryngoscope blades are inexpensive and carry a lower risk of infection compared with metal reusable blades, but their efficiency during rapid sequence induction remains a matter of debate. The authors therefore compared plastic and metal blades during rapid sequence induction in a prospective randomized trial. METHODS Two hundred eighty-four adult patients under...

متن کامل

Comparison of single-use and reusable metal laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia: a multicenter cluster randomized study.

BACKGROUND Single-use metal laryngoscope blades are cheaper and carry a lower risk of infection than reusable metal blades. The authors compared single-use and reusable metal blades during rapid sequence induction of anesthesia in a multicenter cluster randomized trial. METHODS One thousand seventy-two adult patients undergoing general anesthesia under emergency conditions and requiring rapid...

متن کامل

a comparison of teachers and supervisors, with respect to teacher efficacy and reflection

supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...

15 صفحه اول

Comparison of two Macintosh laryngoscope blades in 300 patients.

BACKGROUND There are two forms of Macintosh laryngoscope blade. Compared with the standard blade, the English blade is longer, its curve is more continuous across the entire length of the blade, the flange of the blade continues much closer to the blade tip, and the height of the flange is shorter. METHOD We studied 300 patients to compare the ease of laryngoscopy with each type of Macintosh ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of research in medical sciences

جلد ۱۲، شماره ۱، صفحات ۴۱-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023