pillow-shape base isolation system and its seismic behavior
نویسندگان
چکیده
in this paper a new isolating system is introduced for short to mid-rise buildings. in comparison to conventional systems such as lrb and hrb, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. this system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. by using this system in two perpendicular directions, building can move in all horizontal directions with respect to its foundation. due to the pillow shape of the roller, this system has self-centering capability which causes it to return to its original position after the earthquake. the rolling friction force between pillows and their bed creates some damping in the system which prevents it from further oscillation after earthquake excitations diminish. the purpose of this study is to evaluate the proposed isolation system’s performance under different earthquake excitations. first of all general features of the proposed isolators have been introduced followed by the analytical equations of the system. vertical bearing capacity and the effects of the thickness of pillows has been investigated using abaqus software. it has been shown that for a pair of pillows of 58 cm width, 45 cm height and 100 cm length the vertical load bearing capacity of the system is more than 300 tons. the period of system with respect to the height and radius of curvature of the rollers, and seismic response of a building, assumed as a rigid body resting on isolators, has been studied subjected to simultaneous effects of horizontal and vertical excitations. it has been shown that the proposed system can reduce the absolute acceleration in the building around 78% in average, while the building’s maximum displacement is around 1.77 times of the ground in average.
منابع مشابه
Pillow-Shape Base Isolation System and Its Seismic Behavior
In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two ...
متن کاملDerivation of Equation of Motion for the Pillow-Shape Seismic Base Isolation System
Rolling-based seismic isolation systems, in which rollers of circular or non-circular section are used, are less expensive and easier to manufacture. However, this type of isolation suffers from either lack of restoring or re-centering capability, or weakness against uplift forces. To resolve the first shortcoming the use of elliptical as well as pillow-shape rolling parts has been suggested, a...
متن کاملderivation of equation of motion for the pillow-shape seismic base isolation system
rolling-based seismic isolation systems, in which rollers of circular or non-circular section are used, are less expensive and easier to manufacture. however, this type of isolation suffers from either lack of restoring or re-centering capability, or weakness against uplift forces. to resolve the first shortcoming the use of elliptical as well as pillow-shape rolling parts has been suggested, a...
متن کاملSeismic Response Reduction of Structures using Smart Base Isolation System
In this study, control performance of a smart base isolation system consisting of a friction pendulum system (FPS) and a magnetorheological (MR) damper has been investigated. A fuzzy logic controller (FLC) is used to modulate the MR damper so as to minimize structural acceleration while maintaining acceptable base displacement levels. To this end, a multi-objective optimization scheme is used t...
متن کاملApplication of Shape Memory Alloys in Seismic Isolation: A Review
In the last two decades, there has been an increasing interest in structural engineering control methods. Shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. Characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...
متن کاملSeismic Response Control Using Base Isolation Strategy
Earthquakes are one of the natural hazards that occur due to sudden violent movement of earth’s surface which releases energy and has destructive power in many parts of the world. The development of recent technologies for the control of seismic hazards catches the attention of structural engineers to make the structures seismically resistant. The seismic base isolation technique is a passive p...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
journal of structural engineering and geo-techniquesناشر: civil engineering & construction research center (ccrc), qiau
ISSN
دوره 5
شماره 2 2015
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023