a conductometric urea biosensor by direct immobilization of urease on pt electrode

نویسندگان

hedayatollah ghourchian

ahmad moulaie rad

hossein elyasvandi

چکیده

urease was immobilized on platinum electrode both by chemical binding and electropolymerization.the conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 m and linear dynamic range from 4.9×10-5 to 5.8×10-3 m for urea concentration when the enzyme is covalently immobilized on pt electrodes. conductometric transducers respond to the changes in ionic strength thereby leading to uncontrolled inaccuracies. such interferences were effectively suppressed by here the use of differential sensor pairs. it was shown that measurements in diluted fluids are possible with the use of areference sensor having no immobilized enzyme.specifically, the sensor constructed by covalent binding provided more reproducible responses than that prepared by electropolymerization. namely the former preserved 80% of its initial activity over a period of 25 days. in order to provide more reproducibility,a method was developed for regeneration of the sensor surface so that, the renewed sensor would responded to urea almost as new.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode

Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...

متن کامل

Covalent immobilization of urease on polypyrrole microspheres for application as a urea biosensor

Urease has been covalently immobilized on polypyrrole microspheres chemically linked to conducting polypyrrole-polyvinyl sulfonate (PPY-PVS) films. These films were electrochemically prepared during 5 7 min at a constant current of 2 mA using indium tin oxide (ITO) glass plates as the working electrode, and a standard calomel electrode as the reference electrode. Urease covalently linked to pol...

متن کامل

A Novel Conductometric Urea Biosensor with Improved Analytical Characteristic Based on Recombinant Urease Adsorbed on Nanoparticle of Silicalite.

Development of a conductometric biosensor for the urea detection has been reported. It was created using a non-typical method of the recombinant urease immobilization via adsorption on nanoporous particles of silicalite. It should be noted that this biosensor has a number of advantages, such as simple and fast performance, the absence of toxic compounds during biosensor preparation, and high re...

متن کامل

Impedimetric Urea Biosensor Based on Modified Gold Electrode with Urease Immobilized on Glutathione Layer

In this work, a glutathione (GSH) modified gold microelectrode was used for the covalent immobilization of urease biomolecules via the glutaraldehyde-coupling agent. The self-assembled monolayers (SAMs) onto the gold surface was investigated by using the electrochemical impedance spectroscopy measurements (EIS). Before urease grafting, a significant interaction was noticed between urea and the ...

متن کامل

Sol–gel-derived thick-film conductometric biosensor for urea determination in serum

A conductometric urea biosensor based on sol–gel-immobilized urease on a screen-printed inter-digitated array (IDA) electrode has been developed. The screen-printed thick-film IDA electrode has proven to be an excellent conductometric transducer in which the admittance signal was dominated by the conductance signal and the resulting dynamic range was wide enough to be employed for the construct...

متن کامل

Modification of Glucose biosensor using Pt/MWCNTs electrode and optimization by application of taguchi method

In this paper, multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)

ناشر: iranian institute of research and development in chemical industries (irdci)-acecr

ISSN 1021-9986

دوره 23

شماره 2 2004

میزبانی شده توسط پلتفرم ابری doprax.com