developed method application for nitrite ion (no2¯ ) analysis of tib -186 macrophage like cell lines by rapid isocratic hplc system with high sensitive glassy carbon electrochemical detector

نویسندگان

manuchehr ghojaie

bahram goliaei

چکیده

a rapid isocratic method of high performance liquid chromatography system (hplc) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of  trace amount of nitrite ion (no2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. the solid extraction  reversed phase cartridges (sep-pak) are used for deproteinizing and purification of the samples. nitrite ion is the only stable end product of autoxidation of nitric oxide (no) ; which is a highly reactive paramagnetic molecule produced via the enzymatic conversion of l-arginine to l-citroline. the enzyme involved in this process is the inducible nitric oxide synthase (inos), the main isoform of the enzymes in macrophage and macrophage like cell lines such as raw-264, j774, and ic-21. nitrite ion (no2¯) in nanomolar concentration range is measured by the ecd detector with an amperometric cell, applied voltage of + 800 mv and  ag-agcl as the reference electrode. elusion buffer is 8 mm ammonium chloride containing 25% methanol, flow rate of 1 ml/min and column temperature set at 20° c. the reproducibility of sample preparation and analysis had a coefficient of variance (c.v.) less than 10 % in the cell lysates and cell media of the tib-186 cell lines. therefore, this will be a reliable analytical method for the nitrite ion analysis under various conditions of cytokines, lps, irradiation, or other chemical applications for evaluation of the probable over expression of the inducible nitric oxide synthase ( inos ) gene in these type of cells.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developed Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector

A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of  trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction  reversed phase cartridges ...

متن کامل

Developed Method Application for Nitrite Ion (NO2 ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector

A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges (Sep-pak) are used for deprot...

متن کامل

Application of carbon ceramic modified electrode with prussian blue for electrocatalytic oxidation of nitrite ion

A novel chemically modified electrode containing Prussian blue complex was achieved on the surface of glass carbon electrode by sol-gel technique. The electrochemical behavior of modified electrode was characterized by cyclic voltammetry in detail. The film electrode obtained was very stable and exhibited electrocatalytic response for oxidation of nitrite. Results showed at bare GC electrode, a...

متن کامل

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

application of carbon ceramic modified electrode with prussian blue for electrocatalytic oxidation of nitrite ion

a novel chemically modified electrode containing prussian blue complex was achieved on the surface of glass carbon electrode by sol-gel technique. the electrochemical behavior of modified electrode was characterized by cyclic voltammetry in detail. the film electrode obtained was very stable and exhibited electrocatalytic response for oxidation of nitrite. results showed at bare gc electrode, a...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)

ناشر: iranian institute of research and development in chemical industries (irdci)-acecr

ISSN 1021-9986

دوره 24

شماره 1 2005

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023