diagnosis of heat exchanger scales in cooling water systems
نویسندگان
چکیده
an experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. to collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulating heat exchangers can be mentioned. changing the water chemistry and using various inhibitors composition known in the art, the nature of scale deposits formed on the heating elements was studied by scanning electron microscopy (sem) coupled with energy dispersive x-ray instrument. the heat flux of the elements ranges from 9.46 × 104 to 1.45 × 105 j/m2.sec, which depending on the velocity of fluid passing through the orifice of pipe, give rise to skin temperatures of 80 °c to 230 °c. the flow velocities used in this study were 0.21 and 0.46 m/sec. phosphonates and most popular polymers were studied as scale inhibitors.
منابع مشابه
Diagnosis of Heat Exchanger Scales in Cooling Water Systems
An experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. To collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulat...
متن کاملPassive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate
Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملEnhancement of Round Tube and Flat Tube-Louver Fin Heat Exchanger Performance Using Deluge Water Cooling
An experimental study has been conducted to evaluate the performance of a compact round-tube louver-fin condenser, each with frontal areas of 0.25 m in both dry and wet conditions. Deluge water cooling is achieved by incorporating a perforated bottom plate-type water distributor on top of the round tube heat exchanger. Water is used as a refrigerant, and enters the heat exchanger tubes at 35°C ...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)ناشر: iranian institute of research and development in chemical industries (irdci)-acecr