surface coating of red blood cells with monomethoxy poly(ethylene glycol) activated with two different reagents

نویسندگان

fatemeh sarvi

sameereh hashemi najafabadi

ebrahim vasheghani farahani

seyed abbas shojaosadati

چکیده

methoxy poly(ethylene glycol) (mpeg) with molecular mass of 5 kda activated with succinimidyl carbonate and cyanuric chloride, separately was covalently attached to human red blood cells (rbcs). inhibition of agglutination by blood-type specific antisera (anti-d) was employed to evaluate the effect of the polymer coating. the remaining single cells after incubation with anti-d sera were counted using a simple hemocytometer (improved neubauer ruling). the extent of surface coating was evaluated by addition of fitc labeled-anti-d to the cells and recording the fluorescence intensity ratio of fitc-anti-d bound cells of the peg-rbcs versus control (uncoated) rbcs. the morphology of rbcs was evaluated by scanning electron microscopy (sem). the effect of polymer coating, based on the immunological response of rbcs, using two kinds of activated mpeg, at optimum conditions of pegylation was compared. it was found that succinimidyl carbonate at its optimum condition (ph=8.7, temperature =14°c and reaction time =60 min) is more effective than cyanuric chloride at its optimum condition (ph=8.7, temperature =14 °c and reaction time =30 min) for rbc coating with mpeg.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface Coating of Red Blood Cells with Monomethoxy poly(ethylene glycol) Activated with Two Different Reagents

Methoxy poly(ethylene glycol) (mPEG) with molecular mass of 5 kDa activated with succinimidyl carbonate and cyanuric chloride, separately was covalently attached to human red blood cells (RBCs). Inhibition of agglutination by blood-type specific antisera (anti-D) was employed to evaluate the effect of the polymer coating. The remaining single cells after incubation with anti-D sera were cou...

متن کامل

surface coating of islets of langerhans by activated polyethylene glycol

the final treatment for diabetes is transplantation of islets of langerhans. one of the new proposed methods for immunological preservation of transplanted cells is coating of cell surface by polyethylene glycol. in this study, the surface of islets of langerhans was coated by cyanuric chloride activated methoxy polyethylene glycol. the effect of polymer coating, at two different reaction times...

متن کامل

investigating the stability of polymer coating of methoxy polyethylene glycol activated by succinimidyl valerate on the surface of red blood cells at in vitro and in vivo conditions

objective: because of the host immunological system response against the minor blood groups of donor, transfusion in some cases, especially for patients require repeated transfusions (such as people with thalassemia), can be considered as a significant problem.  a proposed way is coating the surface antigens on red blood cells (rbcs) by covalent binding of methoxy polyethylene glycol (mpeg). th...

متن کامل

Direct comparison of liposomal doxorubicin with or without polyethylene glycol coating in C-26 tumor-bearing mice: is surface coating with polyethylene glycol beneficial?

Sterically stabilized liposome is characterized by a surface coating of polyethylene glycol (PEG) or other polymers that can reduce opsonization of the liposome by plasma proteins. It has a higher plasma area under the concentration-time curve (AUC), which is believed to correlate with better therapeutic efficacy. However, the presence of large molecules on the liposomal surface may reduce the ...

متن کامل

Simultaneous Camouflage of Major and Minor Antigens on Red Blood Cell Surface With Activated mPEGs

Background: Host immune system response against blood group antigens is a major problem in blood transfusions, especially for <span style="font-varian...

متن کامل

hemoglobin modified with maleimide - activated polyethylene glycol

We have recently described human hemoglobin surfacemodified with polyethylene glycol (MP4, registered trademark Hemospan) that does not possess the vasoconstrictive properties which have hampered development of some hemoglobin-based oxygen carriers. Based on in vitro studies, we postulated that this lack of vasoconstriction is due to decreased diffusive oxygen transfer in the plasma space as a ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)

ناشر: iranian institute of research and development in chemical industries (irdci)-acecr

ISSN 1021-9986

دوره 27

شماره 3 2008

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023