measurement and modeling of mean ionic activity coefficient in aqueous solution containing nano3 and poly ethylene glycol
نویسندگان
چکیده
potentiometric investigation on {h2o+nano3+peg1500} mixtures were made at t=308.15k, using electrochemical cells with two ion-selective electrodes, (na+ glass) as the cation ion-selective electrode against (no3- solvent-polymer pvc) as the anion ion-selective electrode. the mean ionic activity coefficients of nano3 were measured at different concentrations of nano3 and peg. maximum concentration of electrolyte and peg were 1 mol/kg and 0.12 mol/kg, respectively. the experimental data was modeled by utilizing the modified pitzer equation and the activity coefficient ratio of peg was evaluated by using maxwell’s cross differential relation.
منابع مشابه
Measurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol
Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion-selective electrode. The mean ionic activity coefficients of NaNO3 were measu...
متن کاملA Simplified Perturbation Model for Prediction of Mean Ionic Activity Coefficient in Aqueous Electrolyte Solution
متن کامل
measurement and correlation of the mean ionic activity coefficient of NaCl in the mixed solvent of water and ethanol
متن کامل
Study of Surface Tension of Binary Mixtures of Poly (Ethylene Glycol) in Water and Poly (Propylene Glycol) in Ethanol and its Modeling Using Neural Network
متن کامل
Measurement of poly(ethylene glycol) by cell-based anti-poly(ethylene glycol) ELISA.
Poly(ethylene glycol) (PEG) is increasingly used in clinical and experimental medicine. However, quantification of PEG and PEGylated small molecules remains laborious and unsatisfactory. In this report, we stably expressed a functional anti-PEG antibody on the surface of BALB 3T3 cells (3T3/alphaPEG cells) to develop a competitive enzyme-linked immunosorbent assay (ELISA) for PEG quantification...
متن کاملDegradative properties and cytocompatibility of a mixed-mode hydrogel containing oligo[poly(ethylene glycol)fumarate] and poly(ethylene glycol)dithiol.
Our laboratory is currently exploring synthetic oligo(poly(ethylene glycol)fumarate) (OPF)-based biomaterials as a means to deliver fibroblasts to promote regeneration of central/partial defects in tendons and ligaments. In order to further modulate the swelling and degradative characteristics of OPF-based hydrogels, OPF crosslinking via a radically initiated, mixed-mode reaction involving poly...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)ناشر: iranian institute of research and development in chemical industries (irdci)-acecr
ISSN 1021-9986
دوره 32
شماره 2 2013
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023