simultaneous determination of sulfamethoxazole and phthalazine by hplc and multivariate calibration methods

نویسندگان

sorayya asadi

parvin gharbani

چکیده

two multivariate calibration methods are compared for the simultaneous chromatographic determination and separation of sulfamethoxazole (smx) and phthalazine (phz) by high performance liquid chromatography (hplc). multivariate calibration techniques such as classical least squares (cls) and inverse least squares (ils) were introduced into hplc to determine the quantification by using uv detector at 235, 250, 260 and 270 nm. sixteen binary mixtures of smx and phz as calibration set and eight binary mixtures as prediction set were used. results show that, relative errors of prediction (rep) of cls and ils for smx and phz were 0.17%, 0.63% and o.15%, 0.56%, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of Sulfamethoxazole and Phthalazine by HPLC and Multivariate Calibration Methods

Two multivariate calibration methods are compared for the simultaneous chromatographic determination and separation of Sulfamethoxazole (SMX) and Phthalazine (PHZ) by High Performance Liquid Chromatography (HPLC). Multivariate calibration techniques such as Classical Least Squares (CLS) and Inverse Least Squares (ILS) were introduced into HPLC to determine the quantification by using UV d...

متن کامل

Simultaneous Determination of Sulfamethoxazole and Phthalazine by HPLC and Multivariate Calibration Methods

Two multivariate calibration methods are compared for the simultaneous chromatographic determination and separation of Sulfamethoxazole (SMX) and Phthalazine (PHZ) by High Performance Liquid Chromatography (HPLC). Multivariate calibration techniques such as Classical Least Squares (CLS) and Inverse Least Squares (ILS) were introduced into HPLC to determine the quantification by using UV detecto...

متن کامل

Simultaneous spectrophotometric determination of lidocaine and hydrocortisone acetate in pharmaceutical preparations by multivariate calibration methods

The multivariate calibration method, partial least square regression (PLS) was applied for thesimultaneous spectrophotometric determination of Lidocaine (LID) and Hydrocortisone acetate(HCA) in their mixtures. The parameters of chemometric technique were optimized and theproposed method was validated with synthetic samples and applied to analyze these drugs inpharmaceutical products with good a...

متن کامل

simultaneous spectrophotometric determination of amlodipine and metoprolol by principal componentregression multivariate calibration and comparison with hplc

multi-drug therapy in high blood pressure is appreciated to achieve a normalblood pressure.a simple spectrophotometric method based on principal component analysis has been proposed for simultaneous determination of amlodipine (amd) and metoprolol(met) in pharmacutical preparations. calibration matrix contains 3.402 µgml -1 to 170.130 µgml -1 and from 13.060 µgml -1 to 65.3 µgml -1 amlodipine a...

متن کامل

simultaneous spectrophotometric determination of lidocaine and hydrocortisone acetate in pharmaceutical preparations by multivariate calibration methods

the multivariate calibration method, partial least square regression (pls) was applied for thesimultaneous spectrophotometric determination of lidocaine (lid) and hydrocortisone acetate(hca) in their mixtures. the parameters of chemometric technique were optimized and theproposed method was validated with synthetic samples and applied to analyze these drugs inpharmaceutical products with good a...

متن کامل

Simultaneous spectrophotometric determination of ampicillin and penicillin in human plasma using multivariate calibration

An analytical methodology based on spectrophotometric and partial least squares (PLS) algorithm for thesimultaneous determination of ampicillin and penicillin in human plasma was developed and validated. Themultivariate model was developed as a binary calibration model and it was built and validated with anindependent set of synthesis and real samples in presence of matrix. It is shown how a de...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)

ناشر: iranian institute of research and development in chemical industries (irdci)-acecr

ISSN 1021-9986

دوره 32

شماره 2 2013