an electrochemical measurement for evaluating the cathodic disbondment of buried pipeline coatings under cathodic protection

نویسندگان

farzaneh akvan

jaber neshati

jamshid mofidi

چکیده

steel pipelines are susceptible to corrosion by the action of corrosive substance in the environment and one of the most common failure modes in buried pipeline coatingis cathodic disbondment. consequently, electrochemical impedance spectroscopy (eis) was used to assess the effect of three important parameters, the thickness of coating, the artificial defect and electrolyte type, on cathodic disbondment, according to astm g8. experiments were done in 3.5 % wt nacl, kcl and cacl2 solutions at room temperature with different coating thicknesses (354, 483 and 1014μm) and several artificial defects diameters (3, 6 and 9 mm). immersion time was 28 days and during this period, a -1.5 v cathodic potential (vs. sce) was applied. further, the eis measurements were done in open circuit potential (ocp). investigations showed that a thick polyurethane coating was highly resistant to cathodic disbondment in intact areas and that coating thickness increases caused decreases in the rate of cathodic disbondment in areas with defects. on the other hand, the evaluation on artificial defects showed disputable results, though with no logical correlations between artificial defects’ diameters and any disbonded area individually. in addition, assessment on electrolyte type showed the rate of cathodic disbonding might be classified after two parameters: solubility and mobility of ions. so, the disbonded area was dependent on the cation type in the electrolyte, and the anion diffusion had less effect in the cathodic disbondment process. furthermore, the comparison between the cations and the anions in solution showed that the most important coating disbondments occurred when cations / anions are in a 1:1 ratio.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Electrochemical Measurement for Evaluating the Cathodic Disbondment of Buried Pipeline Coatings under Cathodic Protection

Steel pipelines are susceptible to corrosion by the action of corrosive substance in the environment and one of the most common failure modes in buried pipeline coatingis cathodic disbondment. Consequently, Electrochemical Impedance Spectroscopy (EIS) was used to assess the effect of three important parameters, the thickness of coating, the artificial defect ...

متن کامل

APPLIED OF IMPRESSED CURRENT CATHODIC PROTECTION DESIGN FOR FUEL PIPELINE NETWORK AT NAVAL BASE

Indonesian Navy (TNI AL) is the main component for Maritime Security and Defence. Because of that, TNI AL needs Indonesian Warship (KRI) to covered Maritime area. The main requirement from KRI is fulfilled by demand. To pock of fuel demand from KRI at Naval Base, it needs a new pipeline of fuel distribution network system. The pipeline network system used for maximum lifetime must be protected ...

متن کامل

Electrochemical Impedance Spectroscopy as a Method to Predict Delamination of Coated Steel in Cathodic Disbondment Tests

A study was undertaken using electrochemical impedance spectroscopy to measure delamination and compare that measurement, which can be performed on the sample repeatedly, with the accepted method of cathodic disbondment (CD) testing, the major drawback of which is that this measurement can only be done once on the sample; in reaching this goal, EIS could be used to predict delamination based on...

متن کامل

4.18 Principles of Cathodic Protection

4.18.1 Historical Background 2747 4.18.2 Electrochemical Principles 2748 4.18.2.1 Aqueous Corrosion 2748 4.18.2.2 Cathodic Protection 2748 4.18.2.3 Oxygen Reduction 2749 4.18.2.4 Hydrogen Evolution 2750 4.18.3 Methods of Applying Cathodic Protection 2751 4.18.3.1 Impressed Current Method 2751 4.18.3.2 Sacrificial Anodes 2752 4.18.4 Proof of Protection 2753 4.18.4.1 Steel 2753 4.18.4.2 Other Met...

متن کامل

Energy Management Strategy of Stand-alone Photovoltaic System in Cathodic Protection Pipeline

‎ In this paper, the stand-alone photovoltaic system for cathodic protection of underground pipelines is presented. The proposed system offers continuous and automatic adjustment of the applied voltage so that the buried pipelines receive the exact current. A modified perturb and observe (P&O) algorithm for maximum power point tracking (MPPT) is used to improve dynamic and steady state performa...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)

ناشر: iranian institute of research and development in chemical industries (irdci)-acecr

ISSN 1021-9986

دوره 34

شماره 2 2015

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023