ordered nanoporous carbon based solid-phase microextraction for the analysis of nitroaromatic compounds in aqueous samples
نویسندگان
چکیده
in this paper, the possibility of using a new ordered nanoporous carbon as a new fiber in headspace solid phase microextraction (hs-spme) to determine of mononitrotoluenes (mnts) in waste water is demonstrated. the structural order and textural properties of the ordered nanoporous carbon were studied by x ray diffraction (xrd), scanning electron microscopy (sem) images and nitrogen adsorption isotherms. the analysis was done on a gas chromatograph equipped with flame ionization detector and capillary column. the main factors affecting the mnt compounds extraction such as rate of stirring sample solution, sample solution volume, ion strength of sample solution, extraction time and temperaturehave been investigated and established. optimization of these parameters was done by taguchi method and orthogonal array design (oad). the effects of these parameters were investigated using the analysis of variance (anova). under the optimum conditions, recovery values were between 87.1% and 106.2%, limit of detections (lods) ranged from 0.01 mg/l to 0.16 mg/l and linear dynamic range (ldr) of 0.5–400 mg/l was obtained. relative standard deviation of single fiber and fiber-to-fiber (n=4) was in the range of 3.7-4.2% and 7.3-8.9%. performance of the present method was evaluated for extraction and determination of nitroaromatic compounds in wastewater samples in the range of microgram per liter and satisfactory results were obtained.
منابع مشابه
Ordered Nanoporous Carbon Based Solid-Phase Microextraction for the Analysis of Nitroaromatic Compounds in Aqueous Samples
In this paper, the possibility of using a new ordered nanoporous carbon as a new fiber in headspace solid phase microextraction (HS-SPME) to determine of mononitrotoluenes (MNTs) in waste water is demonstrated. The structural order and textural properties of the ordered nanoporous carbon were studied by X Ray Diffraction (XRD), Scanning Electron Microscopy (SEM) images and nitrogen adsorpti...
متن کاملOrdered nanoporous carbon (CMK-3) coated fiber for solid-phase microextraction of benzene and chlorobenzenes in water samples
Nanoporous carbons (CMK-3) were prepared and have been used as a fiber coating for headspace solid phase microextraction (HS-SPME). The prepared materials were characterized by Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD) and N2 adsorption/desorption isotherms. The efficiency of the fiber was evaluated using a gas chromatography (GC) system for the extraction of benzene (B) and c...
متن کاملHCl- Etched Steel Fiber for Determination of Phthalates in Water Samples by Solid-Phase Microextraction
In the present work, a stainless steel wire was etched by hydrochloric acid during a chemical etching process. The obtained black layer on the surface of the fiber was used as sorbent for extraction of trace amount of phthalates in the aqueous samples by solid phase microextraction. New fiber efficiency was investigated using a home-made solid-phase microextraction (SPME) device and gas chr...
متن کاملApplication of Headspace Solid-Phase Microextraction for Determination of Chloro-Organic Compounds in Sewage Samples
Solid phase microextraction (SPME) has been optimized and applied to the determination of the volatile halogenated compounds (VHCs) and semi-volatile halogenated compounds (SVHCs). Three types of SPME fiber coated with different stationary phases (PDMS-100 mum, CAR/PDMS-75 mum, PDMS/DVB-65 mum) were used to examine their extraction efficiencies for the compounds tested. Experimental parameters ...
متن کاملSolid-phase microextraction and headspace solid-phase microextraction for the determination of polychlorinated biphenyls in water samples.
A solid-phase microextraction (SPME) method has been developed for the quantification of polychlorinated biphenyls (PCBs) in water samples. Parameters such as sampling time, volume of water, volume of headspace, temperature, addition of salts, and agitation of the sample were studied. Because the time for reaching equilibrium between phases takes several hours or days, depending on the experime...
متن کاملSolid-phase microextraction for herbicide determination in environmental samples.
Liquid-liquid extraction or solid-phase extraction followed by gas chromatography (GC) or high-performance liquid chromatography are traditional herbicide residue determination methods for environmental samples. Solid-phase microextraction (SPME) is a solventless, fast, and sensitive alternative herbicide residue extraction method that can be applied to numerous environmental matrices. The obje...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
iranian journal of chemistry and chemical engineering (ijcce)ناشر: iranian institute of research and development in chemical industries (irdci)-acecr
ISSN 1021-9986
دوره 33
شماره 4 2014
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023