color and cod removal from waste water containing acrylic water base color using fenton's oxidation process

نویسندگان

sh moradianfard

j ghorbani

k bakhshy

چکیده

degradation of acrylic water base color from synthetic wastewater by the fenton process was performed. experiments were conducted on the sample containing 100 and 400 mg/l of acrylic water base color. the study was performed for searching optimum values of feso4 and h2o2 concentration, ph and temperature. the h2o2 requirement seems to be related to initial cod of the sample. feso4/ h2o2 ratios found were not changed for .the temperature affected the cod removal significantly at high degrees.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Color and COD removal from waste water containing acrylic water base color using Fenton's oxidation process

Degradation of acrylic water base color from synthetic wastewater by the Fenton process was performed. Experiments were conducted on the sample containing 100 and 400 mg/l of Acrylic water base color. The study was performed for searching optimum values of FeSO4 and H2O2 concentration, pH and temperature. The H2O2 requirement seems to be re...

متن کامل

Color and COD removal from waste water containing acrylic water base color using Fenton's oxidation process

Degradation of acrylic water base color from synthetic wastewater by the Fenton process was performed. Experiments were conducted on the sample containing 100 and 400 mg/l of Acrylic water base color. The study was performed for searching optimum values of FeSO4 and H2O2 concentration, pH and temperature. The H2O2 requirement seems to be re...

متن کامل

Color and COD removal from waste water containing acrylic water base color using Fenton's oxidation process

Degradation of acrylic water base color from synthetic wastewater by the Fenton process was performed. Experiments were conducted on the sample containing 100 and 400 mg/l of Acrylic water base color. The study was performed for searching optimum values of FeSO4 and H2O2 concentration, pH and temperature. The H2O2 requirement seems to be re...

متن کامل

Color and COD removal from waste water containing acrylic water base color using Fenton's oxidation process

Degradation of acrylic water base color from synthetic wastewater by the Fenton process was performed. Experiments were conducted on the sample containing 100 and 400 mg/l of Acrylic water base color. The study was performed for searching optimum values of FeSO4 and H2O2 concentration, pH and temperature. The H2O2 requirement seems to be re...

متن کامل

color and cod removal from waste water containing acrylic water base color using fenton's oxidation process

degradation of acrylic water base color from synthetic wastewater by the fenton process was performed. experiments were conducted on the sample containing 100 and 400 mg/l of acrylic water base color. the study was performed for searching optimum values of feso4 and h2o2 concentration, ph and temperature. the h2o2 requirement seems to be related to initial cod of the sample. feso4/ h2o2 ratios ...

متن کامل

Color and COD removal from wastewater containing Reactive Black 5 using Fenton's oxidation process.

In this study, Reactive Black 5 (RB5) was removed from synthetic wastewater using Fenton's oxidation (FO) process. Experiments were conducted on the samples containing 100 and 200 mg l(-1) of RB5 to remove the dye toxicity. Seventy-five milligram per litre of RB5 caused 25% toxicity on 24-h born daphnids whereas 100 mg l(-1) of RB5 displayed 100% toxicity on Daphnia magna. The study was perform...