determination of phenol and carvacrol in honey samples using dispersive liquid-liquid microextraction and experimental design for optimization
نویسندگان
چکیده
a very simple, rapid and sensitive dispersive liquid-liquid microextraction (dllme) followed by gas chromatography and flame ionization detection (gc-fid) was developed for the determination of phenol and carvacrol in honey samples. a mixture of 100 µl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. thereby a cloudy solution was formed. after centrifuging, the fine droplets of extraction solvent were sedimented in the bottom of the conical test tube. sedimented phase (0.6 µl) was injected into the gc-fid system. experimental parameters which control the performance of dllme, such as type and volumes of extraction and disperser solvents, ph, salt effect and extraction time were investigated. under optimum conditions obtained by the response surface methodology, the method was found to be linear in the range of 10-200 mg l-1. the limits of detection for phenol and carvacrol were 4.15 and 3.9, respectively, and the extraction recovery ranged from 67-97.3%.
منابع مشابه
Determination of Phenol and Carvacrol in Honey Samples Using Dispersive Liquid-Liquid Microextraction and Experimental Design for Optimization
A very simple, rapid and sensitive dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography and flame ionization detection (GC-FID) was developed for the determination of phenol and carvacrol in honey samples. A mixture of 100 µl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. Thereby a cloudy sol...
متن کاملDetermination of Phenol and Carvacrol in Honey Samples Using Dispersive Liquid- Liquid Microextraction and Experimental Design for Optimization
A very simple, rapid and sensitive dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography and flame ionization detection (GC-FID) was developed for the determination of phenol and carvacrol in honey samples. A mixture of 100 μl dichloromethane (extraction solvent) and 0.5 ml acetonitrile (disperser solvent) was rapidly injected into sample solution. Thereby a cloudy sol...
متن کاملhydrochlorothiazide detection in urine samples by hplc-dad and experimental design dispersive l-l microextraction
hydrochlorothiazide (hct) is a diuretic agent which is shown to be effective in the treatment of hypertension. literature reports have demonstrated that urinary excretion data may be used to assess the bioavailability of various formulations containing this thiazide. also hct consumption by the athletes is one of the drugs which should be regulated by world anti-doping agency (wada), because of...
Spectrophotometric Determination of Formaldehyde in Seawater Samples after In-situ Derivatization and Dispersive Liquid-Liquid Microextraction
In this paper, a simple dispersive liquid-liquid microextraction for the extraction and pre-concentration of formaldehyde in seawater samples followed with spectrophotometric is proposed. Formaldehyde was derivatized in situ with acetyl acetone in the presence of ammonium acetate in a single step. Then it was collected into a mixture of ethanol (disperser solvent) and chloroform (extracting...
متن کاملdetermination of endosulfan in water samples using dispersive liquid-liquid micro-extraction and experimental design for optimization
water contamination due to the wide variety of pesticides used in agriculture is a global environmental pollution problem. in order to reach at sub-î¼gl-1 levels of detection, an efficient extraction technique is required. a simple, fast and economical method, dispersive liquid-liquid micro extraction (dllme), followed by gas chromatography-mass spectrometry was assessed for determining endosul...
متن کاملDetermination of estrogens in water samples using dispersive liquid liquid microextraction and high performance liquid chromatography.
A new method for the analysis of estrogens including estrone (E1), 17b- estradiol (E2) and diethylstilbestrol (DES) in aqueous samples was performed using dispersive liquid liquid microextraction (DLLME) and high- performance liquid chromatography (HPLC). In order to optimize DLLME some important parameters such as type and volume of extraction and disperser solvent, extraction time, ionic stre...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
analytical and bioanalytical chemistry researchناشر: iranian chemical society
ISSN
دوره 3
شماره 1 2016
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023