novel zro2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in pvc matrix

نویسندگان

m. aghaie

k. zare

m. giahi

چکیده

in this work, a novel zr02+ pvc-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (hodbhc) as a new ionophore is presented. the sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 m, with a near nernstian slope of 29.9 ± 0.4 mv per decade in an acidic solution(ph=1). the limit of detection is 8.0 x 1 0 7 m. the electrodes possess advantages of low resistance, very fastresponse time, relatively long lifetimes and, especially, good selectivities relative to a wide variety of othercations. it was used as indicator electrode in potentiometric determination of zro2+ ion by standard additionmethod at ph 1.0 in two samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel ZrO2 ion-selective electrode based on 4,7,13,16,21,24-hexa oxa- 1,10- diazabicyc1o[8,8,8]-hexa cosane as neutral carrier in PVC matrix

In this work, a novel Zr02+ PVC-based membrane sensor based on 4,7,13,16,21,24-hexa oxa-1,10- diazabicyclo[8,8,8]- hexa cosane (HODBHC) as a new ionophore is presented. The sensor displays a linear dynamic rangebetween 1.0x 10-1 and 1.0x10 6 M, with a near Nernstian slope of 29.9 ± 0.4 mV per decade in an acidic solution(pH=1). The limit of detection is 8.0 x 1 0 7 M. The electrodes possess adv...

متن کامل

Determination of Mn2+ in Pharmaceutical Supplements by a Novel Coated Graphite Electrode Based on Zolpidem as a Neutral Ion Carrier

Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...

متن کامل

Fe (II) Ion-Selective Membrane Electrode based onTetra-Phenyl Porphyrin in PVC Matrix

Fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (PVC) matrixmembrane containing neutral carrier tetra phenyl porphyrin (TPP) ionophore. The addition ofsodium tetraphenylborate (NaTPB) and the plasticizer DBP has been found to substantiallyimprove the performance of the sensor. The best performance was obtained with the sensor havinga membrane of composition of TPP...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

A mercury(II) ion-selective electrode based on N,N-dimethylformamide-salicylacylhydrazone as a neutral carrier.

A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x...

متن کامل

fe (ii) ion-selective membrane electrode based ontetra-phenyl porphyrin in pvc matrix

fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (pvc) matrixmembrane containing neutral carrier tetra phenyl porphyrin (tpp) ionophore. the addition ofsodium tetraphenylborate (natpb) and the plasticizer dbp has been found to substantiallyimprove the performance of the sensor. the best performance was obtained with the sensor havinga membrane of composition of tpp...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of physical & theoretical chemistry

ISSN

دوره 3

شماره 3 2015

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023