steel plate characteristic effecting on composite coupled beam at concrete shear wall

نویسندگان

mohammad-kazem sharbatdar

mohammad ali kafi

amin behrad

چکیده

composite couple beams are the concrete elements consisting of longitudinal bars and steel plate, therefore suitable for shear transferring in couple shear walls with arranged gates in its height. in this paper, after modeling couple beams with and without steel plates with f.e methods and calibration the models with experimental results, effects of parameters such as thickness, height, length and yielding strength of the steel plates located in concrete couple composite beam have been investigated on the ductility, energy dissipation and capacity. the results were illustrated that if the plate thickness would be increased by four times, ductility and energy dissipation capacity were decreased 15.6 and 14.7 percent and also loading capacity was enhanced up to 25 percent, respectively. and also the plate height and length didn’t have influence on above mentioned parameters. furthermore, by 80 and 280 percent enhancement in yielding plate strength, ductility and energy dissipation capacity were decline 10.8 to 23.9 and 8.9 to 21.7 percent and also 19, 33 percent enhancement in loading capacity was happened.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Steel Plate Characteristic Effecting on Composite Coupled Beam at Concrete Shear Wall

Composite couple beams are the concrete elements consisting of longitudinal bars and steel plate, therefore suitable for shear transferring in couple shear walls with arranged gates in its height. In this paper, after modeling couple beams with and without steel plates with F.E methods and calibration the models with experimental results, effects of parameters such as thickness, height, length ...

متن کامل

Seismic Performance of Steel Plate-Reinforced Concrete Composite Shear Wall

In tall buildings the reinforced concrete (RC) shear wall is one of the predominant structural components used to resist lateral loads induced by earthquakes around the world. Previous research demonstrated that shear walls displayed a sudden loss in lateral capacity due to the wall corner and web crushing in the plastic zone. In addition, it was found that large shear distortions in shear wall...

متن کامل

Comparison of plasticity and stiffness of steel shear walls with composite steel plate shear wall

The steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. Composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...

متن کامل

comparison of plasticity and stiffness of steel shear walls with composite steel plate shear wall

the steel shear wall and composite steel plate shear wall is introduced in recent three decade and is considered and is spread rapidly. composite steel plate shear wall which is made of a layer of thin steel sheet with coating of reinforced concrete in one or both sides of steel palate is considered a third generation of resistance shear walls against lateral loads that in addition to increasin...

متن کامل

Structural Behavior of Axially Loaded Composite Concrete-steel Plate Shear Walls

composite concrete-steel plate shear walls are the most critical resisting structural members that resist lateral and axial loads. This type of wall consisting of two steel faceplates presenting the outer skin, infill concrete and shear connectors which are used to provide the composite action of the steel faceplates with infill concrete in order to increase the strength and to reduce the local...

متن کامل

Investigation of channel shear connectors for composite concrete and steel T-beam

This paper evaluates the behavior of channel shear connectors, embedded in a concrete slab, with different concrete materials. The results of a series of limited push-out specimens were presented and discussed. The push-out tests comprise of channel shear connectors in different types of concrete. Reinforcement was included in some specimens, as well. The results showed that using reinforcement...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of rehabilitation in civil engineering

ناشر: semnan university

ISSN 2345-4415

دوره 3

شماره 1 2015

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023