detection and determination of groundwater contamination plume using time-lapse electrical resistivity tomography (ert) method

نویسندگان

s. moghaddam

s. dejpasand

a. kamkar rohani

s. parnow

m. ebrahimi

چکیده

protection of water resources from contamination and detection of the contaminants and their treatments are among the essential issues in the management of water resources. in this work, the time-lapse electrical resistivity tomography (ert) surveys were conducted along 7 longitudinal lines in the downstream of the latian dam in jajrood (iran), in order to detect the contamination resulting from the direct injection of a saltwater solution in to the saturated zone in the area. to investigate the pollutant quantities affecting the resistivity of this zone, the temperature and electrical conductivity measurement were carried out using a self-recording device during 20 days (before and after the injection). the results obtained from the self-recording device measurements and ert surveys indicated that in addition to the salt concentration changes in water, the resistivity changes in the saturated zone were dependent on other factors such as the lithology and absorption of contaminants by the subsurface layers. furthermore, the expansion of contamination toward the geological trend, sedimentation, and groundwater flow direction of the area were shown.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection and determination of groundwater contamination plume using time-lapse electrical resistivity tomography (ERT) method

Protection of water resources from contamination and detection of the contaminants and their treatments are among the essential issues in the management of water resources. In this work, the time-lapse electrical resistivity tomography (ERT) surveys were conducted along 7 longitudinal lines in the downstream of the Latian dam in Jajrood (Iran), in order to detect the contamination resulting fro...

متن کامل

Time-lapse electrical resistivity tomography of a water infiltration test on Johannishus Esker, Sweden

Managed aquifer recharge (MAR) is an efficient way to remove organic matter from raw water and, at the same time, reduce temperature variation. Two MAR sites were constructed by Karlskrona municipality on Johannishus Esker in Sweden. One of these sites, Vång, was monitored for electrical conductivity and electrical resistivity (using electrical resistivity tomography ERT) during a 9-week tracer...

متن کامل

detection of underground tunnels using electrical resistivity and refraction seismic tomography methods

geophysical techniques remain the only ways to remotely and non-destructively sense the earth’s near subsurface and as such have the most promising prospect for rapid and accurate detection of underground tunnels. today, electrical resistivity and seismic refraction geophysical methods have been greatly developed to identify structures and underground cavities. in this study, the ability of the...

متن کامل

Anatomy of terminal moraine segments and implied lake stability on Ngozumpa Glacier, Nepal, from electrical resistivity tomography (ERT)

Moraine-dammed lakes at debris-covered glaciers are becoming increasingly common and pose significant outburst flood hazards if the dam is breached. While moraine subsurface structure and internal processes are likely to influence dam stability, only few sites have so far been investigated. We conducted electrical resistivity tomography (ERT) surveys at two sites on the terminal moraine complex...

متن کامل

IP4DI: A software for time-lapse 2D/3D DC-resistivity and induced polarization tomography

We propose a 2D/3D forward modelling and inversion package to invert direct current (DC)-resistivity, time-domain induced polarization (TDIP), and frequency-domain induced polarization (FDIP) data. Each cell used for the discretization of the 2D/3D problems is characterized by a DC-resistivity value and a chargeability or complex conductivity for TDIP/FDIP problems, respectively. The governing ...

متن کامل

Imaging Hydrological Processes in Headwater Riparian Seeps with Time-Lapse Electrical Resistivity.

Delineating hydrologic and pedogenic factors influencing groundwater flow in riparian zones is central in understanding pathways of water and nutrient transport. In this study, we combined two-dimensional time-lapse electrical resistivity imaging (ERI) (depth of investigation approximately 2 m) with hydrometric monitoring to examine hydrological processes in the riparian area of FD-36, a small ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of mining and environment

ناشر: university of shahrood

ISSN 2251-8592

دوره

شماره Articles in Press 2015

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023