a review of algorithms for segmentation of optical coherence tomography from retina
نویسندگان
چکیده
optical coherence tomography (oct) is a powerful imaging modality used to image various aspects of biological tissues, such as structural information, blood flow, elastic parameters, change of polarization states, and molecular content [1]. in contrast to oct technology development which has been a field of active research since 1991, oct image segmentation has only been more fully explored during the last decade. segmentation, however, remains one of the most difficult and at the same time most commonly required steps in oct image analysis. no typical segmentation method exists that can be expected to work equally well for all tasks [2]. one of the most challenging problems in oct image segmentation is designing a system to work properly in clinical applications. there is no doubt that algorithms and research projects work on a limited number of images with some determinate abnormalities (or even on normal subjects) and such limitations make them more appropriate for bench and not for the bedside. moreover, oct images are inherently noisy, thus often requiring the utilization of 3-d contextual information. furthermore, the structure of the retina can drastically change during disease. nevertheless, oct image segmentation is a rapidly growing and important area and a great deal of efforts went into designing algorithms for automatic segmentation of retinal octs. the important steps of oct image segmentation algorithms may be categorized in to 4 steps: 1) determining a particular range of oct datasets (e.g. 2d, 3d, time domain, spectral domain, macular, onh, etc.) for which the proposed algorithm will work properly; 2) allocating proper values for possible parameters of the algorithm; 3) running the algorithm on determined datasets and acquiring the outcomes (e.g. boundary information, thickness values, classification of normal and abnormal images and etc.); 4) validating the results by comparing with gold standards or getting the confirmation by an expert. here, we review some of the important image segmentation methods for processing retinal oct images. we may classify the oct segmentation approaches into five distinct groups according to the image domain subjected to the segmentation algorithm. let’s define 5 separate families of segmentation approaches: methods applicable to a-scan, b-scan, active contour approaches (frequently in 2-d), analysis methods utilizing artificial intelligence, and segmentation methods using 3d graphs constructed from the 3d oct volumetric images. some details of algorithms representing each class will be discussed in more detail and concluding remarks will be provided to compare the efficiency of different methods in different datasets. it should be noted that intrinsic noisy structure of retinal octs (particularly in old octs and after diseases) makes simple edge detection algorithms unsuitable for this purpose and researchers have tried to develop new algorithms to overcome such problems.
منابع مشابه
A Review of Algorithms for Segmentation of Retinal Image Data Using Optical Coherence Tomography
In the context of biomedical imaging analysis and computer-assisted diagnosis, segmentation analysis is an intense field of research and development. The most difficult part of medical image analysis is the automated localization and delineation of structures of interest. Automated data evaluation is one way of enhancing the clinical utility of measurements. In particular, medical image segment...
متن کاملRetina-simulating phantom for optical coherence tomography.
Optical coherence tomography (OCT) is a rapidly growing imaging modality, particularly in the field of ophthalmology. Accurate early diagnosis of diseases requires consistent and validated imaging performance. In contrast to more well-established medical imaging modalities, no standardized test methods currently exist for OCT quality assurance. We developed a retinal phantom which mimics the th...
متن کاملClinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملExperimental Visualization of Labyrinthine Structure with Optical Coherence Tomography
Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...
متن کاملThe interpretation of optical coherence tomography images of the retina.
PURPOSE To determine the relationship between optical coherence tomography (OCT) images of the retina and retinal substructure in vitro and in vivo. METHODS In vitro, OCT images of human and bovine retina were acquired after sequential excimer laser ablation of the inner retinal layers. Measurements of bands in the OCT images were compared with measurements of retinal layers on histology of t...
متن کاملMacular segmentation with optical coherence tomography.
PURPOSE To develop a software algorithm to perform automated segmentation of retinal layer structures on linear macular optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Inc., Dublin, CA) scan images and to test its performance in discriminating normal from glaucomatous eyes in comparison with conventional circumpapillary nerve fiber layer (cpNFL) thickness measurement. METHODS Fo...