designing and implementing bio-impedance spectoroscopy device by measuring impedance in a mouse tissue

نویسندگان

houman mirzaalian dastjerdi

ramin soltanzadeh

hossein rabbani

چکیده

studies show that any complications including hemorrhage, lack of blood supply, lack of oxygen supply, and death of cells in a tissue, will have a clear effect on electrical properties of that tissue. thus, by measuring impedance of a set of tissues, potential problems of the damaged tissue may be found. since electrical impedance is closely related to the measuring frequency, obviously, every tissue exhibits its own specific impedance according to its electrical properties at each frequency. this research project investigates design and manufacture method of a device for measuring tissue impedance at different frequencies. to this end, design of a multi frequency sinusoidal current source is required. this current source is built using a single harmonic generator sample (dds ad9835) with working frequency (design-point frequency) between 1 hz and 10 mhz and accuracy of 1 hz, and microcontroller (pic16f628) capability. for measurement and display of tissue impedance, arm at91sams256 microcontroller was used. thus, with this hardware created, it shows that there are significant impedance changes between mouse tissues.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Device for Measuring Mechanical Impedance during Dynamic Tasks

Mechanical impedance is an important factor that the central nervous system takes into account while coordinating a motion. This research work thus aims to develop a new measurement for monitoring dynamic changes of mechanical impedance. The method is introduced and validated in the context. The results show that device correctly measures the dynamic force and impedance of an eccentric linear s...

متن کامل

Design and Evaluation of a Portable Device for the Measurement of Bio-impedance- Cardiograph

Electrical impedance of biological matter is known as electrical bioimpedance or simply as bio-impedance. Bio-impedance devices are of great value for monitoring the pathological and physiological status of biological tissues in clinical and home environments. The technological progress in instrumentation has significantly contributed to the progress that has been observed during the last past ...

متن کامل

A new method for measuring osteoclast formation by electrical impedance.

Osteoclasts are important target cells for osteoporosis treatment. Recently, a real-time cell analysis (RTCA) system was developed to observe cell morphology and adhesion; however, the use of RTCA to study osteoclastogenesis has not been reported. Here, we investigated whether osteoclast formation could be monitored in real-time using RTCA. The cell index determined via electrical impedance usi...

متن کامل

Cell Biometrics Based on Bio-Impedance Measurements

Many biological parameters and processes can be sensed and monitored using their impedance as marker (Grimmes, 2008), (Beach. 2005), (Yúfera, 2005), (Radke, 2004), with the advantage that it is a non-invasive, relatively cheap technique. Cell growth, cell activity, changes in cell composition, shapes or cell location are only some examples of processes which can be detected by microelectrode-ce...

متن کامل

Programmable Digital Bio-Impedance Measurement System

The field programmable gate array is the fastest growing technology. The bio-impedance measurement system is implemented in reconfigurable field programmable gate array hardware. The design of bio-impedance measurement system using Xilinx system generator is more convenient and cheaper for revising, if the Bio-impedance measurement system requires parameters changes in practical use, since no n...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...