design and construction of an optical computed tomography scanner for polymer gel dosimetry application

نویسندگان

seyed salman zakariaee

asghar mesbahi

ahmad keshtkar

vahid azimirad

چکیده

polymer gel dosimeter is the only accurate three dimensional (3d) dosimeter that can measure the absorbed dose distribution in a perfect 3d setting. gel dosimetry by using optical computed tomography (oct) has been promoted by several researches. in the current study, we designed and constructed a prototype oct system for gel dosimetry. first, the electrical system for optical scanning of the gel container using a helium-neon laser and a photocell was designed and constructed. then, the mechanical part for two rotational and translational motions was designed and step motors were assembled to it. the data coming from photocell was grabbed by the home-built interface and sent to a personal computer. data processing was carried out using matlab software. to calibrate the system and tune up the functionality of it, different objects was designed and scanned. furthermore, the spatial and contrast resolution of the system was determined. the system was able to scan the gel dosimeter container with a diameter up to 11 cm inside the water phantom. the standard deviation of the pixels within water flask image was considered as the criteria for image uniformity. the uniformity of the system was about ±0.05%. the spatial resolution of the system was approximately 1 mm and contrast resolution was about 0.2%. our primary results showed that this system is able to obtain two-dimensional, cross-sectional images from polymer gel samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymer gel dosimetry on a multislice computed tomography scanner: effect of changing parameters on CTDI.

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

متن کامل

Designing and developing an in-house CCD based optical CT scanner for gel dosimetry

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

متن کامل

Design and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

متن کامل

Accuracy and reproducibility in x-ray computed tomography polymer gel dosimetry

This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۴، شماره ۲، صفحات ۱۳۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023