study of a new design of p-n semiconductor detector array for nuclear medicine imaging by mcnpx simulation

نویسندگان

mohsen hajizadeh-safar

m ghorbani

s khoshkharam

z ashrafi

چکیده

gamma camera is an important apparatus in nuclear medicine imaging. its detection part is consists of a scintillation detector with aheavy collimator. substitution of semiconductor detectors instead of scintillator in these cameras has been effectively studied. in this study, it is aimed to introduce a new design of p-n semiconductor detector array for nuclear medicine imaging. a p-n semiconductor detector composed of n-sno:f, and p‑nio:li, has been introduced through simulating with mcnpx monte carlo codes. its sensitivitywith different factors such as thickness, dimension, and direction of emission photons were investigated. it is then used to configure anew design of an array in one‑dimension and study its spatial resolution for nuclear medicine imaging. one‑dimension array with 39detectors was simulated to measure a predefined linear distribution of tc2 activity and its spatial resolution. the activity distributionwas calculated from detector responses through mathematical linear optimization using linprog code on matlab software. threedifferent configurations of one‑dimension detector array, horizontal, vertical one sided, and vertical double‑sided were simulated. inall of these configurations, the energy windows of the photopeak were ± 1%. the results show that the detector response increaseswith an increase of dimension and thickness of the detector with the highest sensitivity for emission photons 15-30° above the surface.horizontal configuration array of detectors is not suitable for imaging of line activity sources. the measured activity distribution withvertical configuration array, double‑side detectors, has no similarity with emission sources and hence is not suitable for imagingpurposes. measured activity distribution using vertical configuration array, single side detectors has a good similarity with sources.therefore, it could be introduced as a suitable configuration for nuclear medicine imaging. it has been shown that using semiconductorp‑n detectors such as p‑nio:li, n‑sno299_m:f for gamma detection could be possibly applicable for design of a one dimension arrayconfiguration with suitable spatial resolution of 2.7 mm for nuclear medicine imaging.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a study on thermodynamic models for simulation of 1,3 butadiene purification columns

attempts have been made to study the thermodynamic behavior of 1,3 butadiene purification columns with the aim of retrofitting those columns to more energy efficient separation schemes. 1,3 butadiene is purified in two columns in series through being separated from methyl acetylene and 1,2 butadiene in the first and second column respectively. comparisons have been made among different therm...

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

investigating the feasibility of a proposed model for geometric design of deployable arch structures

deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...

simulation and design of electronic processing circuit for restaurants e-procurement system

the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...

15 صفحه اول

a genre analytic study of research papers written by bilingual writers and their beliefs: a case of persian-english writers

تحقیق حاضر گزارشی است از تحلیل بخش مقدمه دو دسته از مقالات که عبارتند از: 11 مقاله از دو نویسنده دوزبانه فارسی زبان, که شامل مقدمه 4 مقاله به زبان انگلیسی و چاپ شده در مجلات بین المللی, مقدمه 3 مقاله به زبان انگلیسی و 4 مقاله به زبان فارسی چاپ شده در مجلات داخلی می شود؛ و 12 مقاله از محققان خارجی که در مجله applied linguistics به چاپ رسیده است. مبنای تئوری این تحلیل ها نظریه سوئلز (1990) یا هما...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۴، شماره ۳، صفحات ۲۳۱-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023