design and fabrication of the control part of a prototype multileaf collimator system

نویسندگان

abdolreza hashemian

mohammad taghi bahreyni toossi

shahrokh nasseri

چکیده

multileaf collimator (mlc) is among the radiation field shaping systems used for conformal radiotherapy and intensity modulation radiation therapy techniques. the mlc system that has been designed and fabricated in this study includes 52 leaves, 52 stepper motors, 2 dc motors, 16 programmable logic controllers (plcs) and one human machine interface (hmi). this system can be mounted on conventional linear accelerators (linac) as an add‑on accessory. the 52 leaves are mounted on two carriages that are moved independently. the leaves sequence acquired from the image processing of computed tomography images is used to arrange leaves. this sequence is saved in a text file. the leaves are arranged by hmi and labview. using hmi it is possible to test the operation of plcs and manually enter the numerical values of the leaves edges. an executable file is developed by labview program, which is graphically user interfaced between the operator and the mlc control system. the projected width of each leaf on the isocenter accelerator (usually at 100 cm from the source) is 10 mm. the positioning accuracy of each leaf is approximately 1.4 mm.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication of the Mechanical Part of a Prototype Multileaf Collimator System

Introduction: Multileaf collimator (MLC) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. Some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. The purpose of this research was ...

متن کامل

Design and Fabrication of the Control Part of a Prototype Multileaf Collimator System

Multileaf collimator (MLC) is among the radiation field shaping systems used for conformal radiotherapy and intensity modulation radiation therapy techniques. The MLC system that has been designed and fabricated in this study includes 52 leaves, 52 stepper motors, 2 DC motors, 16 programmable logic controllers (PLCs) and one human machine interface (HMI). This system can be mounted on conventio...

متن کامل

design and fabrication of the mechanical part of a prototype multileaf collimator system

introduction: multileaf collimator (mlc) is state of the art among the radiation field shaping systems for conformal radiotherapy techniques. some advantages of this system are as follow: reduction of treatment time, higher precision in conforming the radiation field to the projection of the target volume and lowering the chance of errors made by technologists. the purpose of this research was ...

متن کامل

Design and fabrication of a prototype planar undulator

The main goal of this work is to get the fabrication technology of the insertion devices. A prototype undulator with the period of 48mm and the peak magnetic field of 0.75 T has been fabricated using NdFeB-SH35 magnets based on the cooperation between ILSF and NSTRI. The total magnet length is 483 mm and the number of periods is 8. The magnetic parameters of the undulator are determined in orde...

متن کامل

a study on the design of bio-ethanol process from date wastes of sistan and baluchistan province

اتانول کاربردهای متنوعی در صنایع لاستیک سازی، رنگسازی، حلالها ومکمل سوخت خودرو دارد. اتانول برخلاف نفت از جمله مواد تجدیدپذیر محسوب می شود که مشکلات زیست محیطی و آلودگی نیز ایجاد نمی کند. استفاده از اتانول به عنوان مکمل سوختخودروها از جمله مهمترین مصارف صنعتی این ماده بشمار می رود. با توجه به این موضوع تحقیق و توسعه در زمینه تولید اتانول با درجه خلوص بالا در سطح جهان، و نه تنها در کشور های پیشر...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۴، شماره ۴، صفحات ۳۰۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023