longitudinal impedance tomography for blood pressure characterization of valve deformation

نویسندگان

zahra vahabi

rasool amirfattahi

چکیده

aorta is formed in a dynamic environment which gives rise to imbalances between many forces that tend to extend the diameter and length. furthermore, internal forces tend to resist this extension. impedance tomography can show this imbalance to stimulate the stenosis of aortic valve, growth of the elastic, collagen and to effectively reduce the stresses in the underlying tissue. in blood flow, auscultation noises occurred and in the echocardiography decrease in left ventricular ejection speed can be observed. in this paper, we have modeled an aorta based on anatomical studies to simulate natural, 20% and 30% stenosis as usual heart disease to early diagnosis. valve deformation causes different impedance tomography in 3d mesh of aorta as blood pressure. remodeling of aorta and its flow is found when a cylindrical slice of the fully retracted blood aorta is cut longitudinally through the wall.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Longitudinal Impedance Tomography for Blood Pressure Characterization of Valve Deformation

Aorta is formed in a dynamic environment which gives rise to imbalances between many forces that tend to extend the diameter and length. Furthermore, internal forces tend to resist this extension. Impedance tomography can show this imbalance to stimulate the stenosis of aortic valve, growth of the elastic, collagen and to effectively reduce the stresses in the underlying tissue. In blood flow, ...

متن کامل

Electrical Impedance Tomography by Elastic Deformation

This paper presents a new algorithm for conductivity imaging. Our idea is to extract more information about the conductivity distribution from data that have been enriched by coupling impedance electrical measurements to localized elastic perturbations. Using asymtotics of the elds in the presence of small volume inclusions, we relate the pointwise values of the energy density to the measured d...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Characterization of Inclusions in Impedance Tomography

The inverse problem of electrical impedance tomography (EIT) is to recover the conductivity inside an investigated object from boundary measurements of current and voltage. There is a variety of methods to localize inclusions, i.e. domains in which the conductivity is different from the background conductivity such as e.g. the Factorization method. However, these qualitative methods don’t provi...

متن کامل

Invasive Electrical Impedance Tomography for Blood Vessel Detection

We present a novel method for localization of large blood vessels using a bioimpedance based needle positioning system on an array of ten monopolar needle electrodes. The purpose of the study is to develop a portable, low cost tool for rapid vascular access for cooling and controlled reperfusion of cardiac arrest patients. Preliminary results show that localization of blood vessels is feasible ...

متن کامل

Fabrication and characterization of nanofibrous tricuspid valve scaffold based on polyurethane for heart valve tissue engineering

Objective(s): Tissue engineering represents a new approach to solve the current complications of the heart valve replacements by offering viable valve prosthesis with growth and remodeling capability. In this project, electrospinning and dip coating techniques were used to fabricate heart valve constructs from medical grade polyurethane (PU). Methods: Fir...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۵، شماره ۲، صفحات ۹۷-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023