estimation of organ activity using four different methods of background correction in conjugate view method

نویسندگان

ahmad shanei

maryam afshin

masoud moslehi

sedighe rastaghi

چکیده

to make an accurate estimation of the uptake of radioactivity in an organ using the conjugate view method, corrections of physical factors, such as background activity, scatter, and attenuation are needed. the aim of this study was to evaluate the accuracy of four different methods for background correction in activity quantification of the heart in myocardial perfusion scans. the organ activity was calculated using the conjugate view method. a number of 22 healthy volunteers were injected with 17–19 mci of 99mtc‑methoxy‑isobutyl‑isonitrile (mibi) at rest or during exercise. images were obtained by a dual‑headed gamma camera. four methods for background correction were applied: (1) conventional correction (referred to as the gates’ method), (2) buijs method, (3) bgda subtraction, (4) bgdb subtraction. to evaluate the accuracy of these methods, the results of the calculations using the above‑mentioned methods were compared with the reference results. the calculated uptake in the heart using conventional method, buijs method, bgda subtraction, and bgdb subtraction methods was 1.4 ± 0.7% (p < 0.05), 2.6 ± 0.6% (p < 0.05), 1.3 ± 0.5% (p < 0.05), and 0.8 ± 0.3% (p < 0.05) of injected dose (i.d) at rest and 1.8 ± 0.6% (p > 0.05), 3.1 ± 0.8% (p > 0.05), 1.9 ± 0.8% (p < 0.05), and 1.2 ± 0.5% (p < 0.05) of i.d, during exercise. the mean estimated myocardial uptake of 99mtc‑mibi was dependent on the correction method used. comparison among the four different methods of background activity correction applied in this study showed that the buijs method was the most suitable method for background correction in myocardial perfusion scan.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of cumulative kidney activity in pediatric nuclear scan of the bladder using conjugate view method and four different techniques for correcting background radiations

Background: At present, in nuclear medicine to calculate the cumulative activity of various organs, different techniques are being used to correct the background radiations in the conjugate view method. Each of these techniques considers the effect and weight of background radiations to a different extent. These background radiations can cause errors in cumulative activity calculations. The pur...

متن کامل

comparative dna interaction studies of antiviral drug, zidovudine and its complex using different instrumental methods

هدف از این مطالعه بررسی امکان استفاده از داروهای شناخته شده در درمان سایر بیماریها به عنوان داروهای ضد سرطان است. همچنین با استفاده از این داروها در ساختمان کمپلکس فلز می توان شاخص های دارویی بدست آمده را بررسی نمود. داروی ضد ویروس ایدز(hiv)به نام زیدوودین(azt)انتخاب و.کمپلکس.محلول.در.آب[pt(azt)2]cl2سنتزو به روشهای مختلف فیزیکی و شیمیایی شناسایی گردید. بر هم کنش مقایسه ای این دارو و کمپلکس پلا...

15 صفحه اول

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

the effects of error correction methods on pronunciation accuracy

هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۵، شماره ۴، صفحات ۲۵۳-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023