designing a low‑noise, high‑resolution, and portable four channel acquisition system for recording surface electromyographic signal

نویسندگان

akbar pashaei

mohammad reza yazdchi

hamid reza marateb

چکیده

in current years, the application of biopotential signals has received a lot of attention in literature. one of these signals is an electromyogram (emg) generated by active muscles. surface emg (semg) signal is recorded over the skin, as the representative of the muscle activity. since its amplitude can be as low as 50 µv, it is sensitive to undesirable noise signals such as power‑line interferences. this study aims at designing a battery‑powered portable four channel semg signal acquisition system. the performance of the proposed system was assessed in terms of the input voltage and current noise, noise distribution, and synchronization and input noise level among different channels. the results indicated that the designed system had several inbuilt operational merits such as low referred to input noise (lower than 0.56 µv between 8 hz and 1000 hz), considerable elimination of power‑line interference and satisfactory recorded signal quality in terms of signal‑to‑noise ratio. the muscle conduction velocity was also estimated using the proposed system on the brachial biceps muscle during isometric contraction. the estimated values were in then normal ranges. in addition, the system included a modular configuration to increase the number of recording channels up to 96.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing a Low-noise, High-resolution, and Portable Four Channel Acquisition System for Recording Surface Electromyographic Signal

In current years, the application of biopotential signals has received a lot of attention in literature. One of these signals is an electromyogram (EMG) generated by active muscles. Surface EMG (sEMG) signal is recorded over the skin, as the representative of the muscle activity. Since its amplitude can be as low as 50 μV, it is sensitive to undesirable noise signals such as power-line interfer...

متن کامل

A new method for acquisition and analysis of single unit recording data

Single unit recording has been used as a well-known technique to study the electrical behavior of neurons. In this respect, the classical methods are rather expensive. In this study a simple and inexpensive method for single unit recording studies has been introduced. Computer sound card was used for data acquisition. Neural responses were saved via simple sound applicable packages and then ana...

متن کامل

A new method for acquisition and analysis of single unit recording data

Single unit recording has been used as a well-known technique to study the electrical behavior of neurons. In this respect, the classical methods are rather expensive. In this study a simple and inexpensive method for single unit recording studies has been introduced. Computer sound card was used for data acquisition. Neural responses were saved via simple sound applicable packages and then ana...

متن کامل

designing and validating a textbook evaluation questionnaire for reading comprehension ii and exploring its relationship with achievement

در هر برنامه آموزشی، مهم ترین فاکتور موثر بر موفقیت دانش آموزان کتاب درسی است (مک دونو و شاو 2003). در حقیقت ، کتاب قلب آموزش زبان انگلیسی است( شلدن 1988). به دلیل اهمیت والای کتاب به عنوان عنصر ضروری کلاس های آموزش زبان ، کتب باید به دقت ارزیابی و انتخاب شده تا از هرگونه تاثیر منفی بر دانش آموزان جلوگیری شود( لیتز). این تحقیق با طراحی پرسش نامه ارزیابی کتاب که فرصت ارزیابی معتبر را به اساتید د...

15 صفحه اول

Designing a Portable Spoken Dialogue System

Spoken dialogue systems enable the construction of complex applications involving extended, meaningful interactions with users. Building an eeective, generic dialogue system requires techniques and expertise from a number of areas such as natural language, computer-human interaction, and information systems. A key challenge is to design a system through which user-friendly applications can be c...

متن کامل

Portable Fingerprint-Based Attendance Recording & Monitoring System

This paper presented the development of a portable attendance monitoring system based on fingerprint identification that can be used by lecturers to monitor attendance of students. Fingerprint-based identification is one of the oldest method among all biometric or security techniques which has been successfully used in numerous applications. Every person has unique, immutable fingerprints. A fi...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۵، شماره ۴، صفحات ۲۴۵-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023