design and implementation of a portable impedance cardiograph system for non-invasive stroke volume monitoring
نویسندگان
چکیده
measurement of the stroke volume and its changes over time can be very helpful for diagnosis of dysfunctions in the blood circulatory system and monitoring their treatments. impedance cardiography (icg) is a simple method of measuring the stroke volume based on changes in the instantaneous mean impedanceof the thorax. this method has received much attention in the last two decades because it is non-invasive, easy to be used, and applicable for continuous monitoring of the stroke volumeas well as otherhemodynamic parameters. the aim of this study was to developa low cost portable icg system with high accuracy for monitoring stroke volume. the proposed wireless system uses a tetrapolar configuration to measure the impedance of the thorax at 50 khz. the system consists ofcarefully designed precise voltage-controlled current source,biopotential recorder anddemodulator. the measured impedance was analyzed on the computer to determine the stroke volume. after evaluating the system’s electronic performance, its accuracy was assessed by comparing its measurements with the values obtained from doppler echocardiography on 5 participants. an impedance cardiograph was implemented that can noninvasively provide a continuous measure of the stroke volume. the snr of the system was measured above 50db. the experiments revealed that a strongcorrelation (r=0.89) exists between the measurements by the developed system and doppler-echocardiograph (p<0.05). icg as the sixth vital sign can be measured simply and reliably by the developed system, but more detailed validation studies should be conducted to evaluate the system performance. there is a good promise to upgrade the system to a commercial version domestically for clinical use in the future .
منابع مشابه
قلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی
Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...
متن کاملDesign and Evaluation of a Portable Device for the Measurement of Bio-impedance- Cardiograph
Electrical impedance of biological matter is known as electrical bioimpedance or simply as bio-impedance. Bio-impedance devices are of great value for monitoring the pathological and physiological status of biological tissues in clinical and home environments. The technological progress in instrumentation has significantly contributed to the progress that has been observed during the last past ...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولdesign, implementation and evaluation of a potato yield monitoring system
in this paper the design, implementation, and evaluation of an experimental-scale potato yield monitoring system is presented. the main objective of this research was to develop a method for accurate mapping of potato yield. at the first stage an instantaneous yield monitoring system was mounted on a potato harvesting machine. this system consisted of a weighing tray, two load cells, a shaft rp...
متن کاملStandardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution.
Since its introduction by Kubicek and colleagues, impedance cardiography has been suggested as a non-invasive, simple, safe and cost-effective method of measuring stroke volume. Several controversial reports on its validity have been published. Pitfalls of this method included the nature of the electrode system and the validity of the equations. Therefore, the purpose of this study was to compa...
متن کاملA new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves
BACKGROUND In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP) is presented, that measures the average stroke volume (SV) for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition) with six independent electrode...