comparison of accuracy in calculation of absorbed dose to patients following bone scan with 99mtc-mdp by two different background correction methods

نویسندگان

daryoush shahbazi-gahrouei

mehri damoori

mohammad bagher tavakoli

masoud moslehi

چکیده

to improve the accuracy of the activity quantification and the image quality in scintigraphy, scatter correction is a vital procedure. the aim of this study is to compare the accuracy in calculation of absorbed dose to patients following bone scan with 99m tc-marked diphosphonates ( 99m tc-mdp) by two different methods of background correction in conjugate view method. this study involved 22 patients referring to the nuclear medicine center of shahid chamran hospital, isfahan, iran. after the injection of 99m tc-mdp,whole-body images from patients were acquired at 10, 60, 90, and 180 min. organ activities were calculated using the conjugate view method by buijs and conventional background correction. finally, the absorbed dose was calculated using the medical internal radiation dosimetry (mird) technique. the results of this study showed that the absorbed dose per unit of injected activity (rad/mci) ± standard deviation for pelvis bone, bladder, and kidneys by buijs method was 0.19 ± 0.05, 0.08 ± 0.01, and 0.03 ± 0.01 and by conventional method was 0.13 ± 0.04, 0.08 ± 0.01, and 0.024 ± 0.01, respectively. this showed that buijs background correction method had a high accuracy compared to conventional method for the estimated absorbed dose of bone and kidneys whereas, for the bladder, its accuracy was low.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the effects of error correction methods on pronunciation accuracy

هدف از انجام این تحقیق مشخص کردن موثرترین متد اصلاح خطا بر روی دقت آهنگ و تاکید تلفظ کلمه در زبان انگلیسی بود. این تحقیق با پیاده کردن چهار متد ارائه اصلاح خطا در چهار گروه، سه گروه آزمایشی و یک گروه تحت کنترل، انجام شد که گروه های فوق الذکر شامل دانشجویان سطح بالای متوسط کتاب اول passages بودند. گروه اول شامل 15، دوم 14، سوم 15 و آخرین 16 دانشجو بودند. دوره مربوطه به مدت 10 هفته ادامه یافت و د...

15 صفحه اول

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

99mTc-MDP whole body bone scan in a case of acute disseminated melioidosis

Melioidosis is a potentially fatal infectious disease occurring predominantly in the tropics, caused by a Gram-negative, motile, rod shaped obligatory aerobic non-spore forming bacillus, Burkholderia pseudomallei. It can produce localised or disseminated disease largely affecting immunocompromised patients. It is a challenge to identify melioidosis early as this disease can manipulate host’s ce...

متن کامل

Comparison of 99mTc-3PRGD2 Integrin Receptor Imaging with 99mTc-MDP Bone Scan in Diagnosis of Bone Metastasis in Patients with Lung Cancer: A Multicenter Study

PURPOSE 99mTc-3PRGD2, a promising tracer targeting integrin receptor, may serve as a novel tumor-specific agent for single photon emission computed tomography (SPECT). A multi-center study was prospectively designed to evaluate the diagnostic accuracy of 99mTc-3PRGD2 imaging for bone metastasis in patients with lung cancer in comparison with the conventional 99mTc-MDP bone scan. METHODS The p...

متن کامل

Three-phase 99mTc-MDP bone scan in a case of pigment villonodular synovitis

Pigment villondular synovitis (PVNS) is a rare synovial condition. The nature of this disorder is usually characterized as benign; however, malignant transformation has also been reported. MRI is the diagnostic modality of choice in evaluating this entity, revealing low T1 and T2 weighted signals and blooming artifact on gradient echo sequences.  Three-phase 99mTc-MDP bone scan has b...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of medical signals and sensors

جلد ۶، شماره ۱، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023