application of a zero-valente iron-per sulfate system to treat petrochemical wastewater with high-total dissolved solids containing para-chlorophenol
نویسندگان
چکیده
results the results showed that the pcp degradation increased with an increase in zvi dosage from 0.056 to 1.4 g/l, an increase in persulfate concentration from 2.5 to 15.0 mm/l, and an increase in zvi to ps molar ratio from 0.1 to 2.5. the optimal initial ph for pcp removal was 5.0 and the maximum removal efficiency of 70% was achieved within 120 minutes. moreover, the zvi catalyst was reused until the third cycle to activate the persulfate and degrade pcp. however, the degradation efficiency of pcp gradually decreased to 51.7% when the zvi reuse time increased. conclusions the results indicate that using zvi/ps system is not an efficient enough method to treat petrochemical effluent, due to the complexity of petrochemical wastewater matrix and high- total dissolved solids (tds) content, as well. background zero-valent iron (zvi) can effectively activate persulfate (ps) generating free sulfate radicals (so4•–), thereby presenting a promising technology to degrade recalcitrant organic contaminants such as para-chlorophenol (pcp) in wastewater. materials and methods effects of dosages of zvi (0.056 - 2.8 g/l), zvi to ps molar ratio (0.1 - 5.0), ps concentration (2.5 - 25.0 mm/l), ph = (3.0 - 11.0), contact time (5 - 240 minutes), and zvi reusability (three cycles) on pcp degradation were examined. objectives the current study aimed to examine the feasibility and application of zvi/ps system through batch experiments to degrade pcp of petrochemical effluent, which its treatment is included in the united states environmental protection agency (usepa) priority pollutant list.
منابع مشابه
Treatment of Wastewater Containing High Concentration of Phenol & Total Dissolved Solids in Moving Bed Biofilm Reactor
Many industries generate phenolic wastewater of acidic nature. Neutralization with sodium hydroxide generates the phenolic wastewater with high TDS. Both phenol and ionic concentration of TDS are inhibitor to biological treatment processes. A study was carried out for biological treatment of phenolic wastewater with high total dissolved solid (TDS) concentration in moving bed biofilm reactor (M...
متن کاملTotal removal of heavy metal from mixed plating rinse wastewater ABSTRACT A mixed plating rinse wastewater containing zinc, hexavalent chromium, trivalent chromium, and cyanide with total dissolved solids
A mixed plating rinse wastewater containing zinc, hexavalent chromium, trivalent chromium, and cyanide with total dissolved solids of 424 mg/1 was treated by a model consisting of a sand filter and ion exchange columns. A strongly acidic cation resin in hydrogen form and a strongly basic anion resin in hydroxide form were used in the columns as cationic and anionic exchangers, respectively. The...
متن کاملبررسی حذف دو-کلروفنل از محیط های آبی با استفاده از فرآیند الکترو/ پرسولفات
Background : 2-chlorophenol is one of the aromatic organic compounds found in large amounts in oil and petrochemical waste waters and chemical methods such as advanced oxidation, etc are used for removal there. Among various AOPs the method derived from sulfate radicals (SO4● -) and per sulfate (S2O82-) activating with heat, UV radiation and transition metals (such as iron ions) is of interest....
متن کاملSafety Evaluation of Nano Iron Zero Valente Green Synthesized: A Comparative Study
Objective(s): Nowadays, examining the toxicity of nanoparticles including the synthesized and functionalized iron nanoparticles using methods like green synthesis is highly considered, due to their increasing usage in various fields of medicine, biology, industrial, and pollution removal. Hence, in this study, the toxicity of the zero valent iron nanoparticles synthesized by plant-Myrtus commun...
متن کاملUse of advanced Fenton and Fenton-like oxidation methods to treat wastewater containing Spiramycin antibiotic
Background and Objective: Antibiotics are hardly decomposable and resistant contaminants in the environment that according to their anti-biological properties, it is necessary to eliminate or reduce the amount of them before entering the environment. Therefore, the main goal of this research is to investigate the Fenton and Fenton-like process efficiency for the treatment of wastewater containi...
متن کاملIsolation and Identification of Bacterial Strains from a Mixed Wastewater Treatment System Used to Treat Petrochemical Effluents
Petrochemical industry generates highly toxic effluents with a large variety of chemicals, being most of them recalcitrant and toxic such as: organic chlorinated compounds (mainly 1,2 dichloroethane) and volatile and semivolatile organic compounds. The most common wastewater treatment systems used in Mexico to treat this kind of effluents are activated sludge and aerated lagoons. Treatibility s...
متن کاملمنابع من