can zeta sperm selection method, recover sperm with higher dna integrity compare to density gradient centrifugation?

نویسندگان

noush afarin khajavi

shahnaz razavi

mohammad mardani

marziyeh tavalaee

چکیده

background: sperm selection for icsi based on morphology and motility might not be relevant to chromatin integrity. thus sperm selection based on sperm characteristics has been suggested. objective: the aim of this study was to compare the efficiency of zeta method with routine density gradient centrifugation method (dgc) for the selection of sperm with higher dna integrity. materials and methods: semen samples were obtained from 63 individuals referring to andrology unit of isfahan fertility and infertility center. semen analysis was carried out according to who criteria. each semen sample was divided into three equal portions. one portion was used as control, the second portion was used for zeta method and the third portion underwent dgc method. each portion was evaluated to dna integrity by tunel assay. student t-test was carried out using spss and p-value lower than 0.05 was considered significant. results: the mean number of sperm dna fragmentation in zeta and dgc methods were significantly decreased compare to the control group (p<0.001). in addition, zeta method was more efficient than the dgc method in the selection of sperm with intact dna (p<0.001). conclusion: the zeta method appears to be a suitable procedure to recover sperm with normal dna integrity.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Sperm Telomere Length between Two Sperm Selection Procedures: Density Gradient Centrifugation and Zeta Potential

Background: Telomeres are particular sequences of DNA located at the end of the eukaryotic chromosomes that are essential for genome integrity. Telomere length in spermatozoa differs among males, as well as spermatozoa. Also, decreased telomere length in spermatozoa of infertile men is associated with the reduction of fertility potential and embryo quality. Density gradient centrifugation (DGC)...

متن کامل

Selection of sperm based on combined density gradient and Zeta method may improve ICSI outcome.

BACKGROUND Reducing the percentage of sperm anomalies in insemination samples remains a goal to be achieved in the intra-cytoplasmic sperm insemination (ICSI) procedure. The aim of this study was to evaluate the efficiency of density gradient centrifugation (DGC) and Zeta methods to recover sperm with intact chromatin, and to evaluate whether the combined DGC/Zeta procedure improved ICSI outcom...

متن کامل

effect of combined density gradient centrifugation on x- and y- sperm separation and chromatin integrity

background: it has been claimed that by using different washing methods, the sperms can be separated according to size, motility, density, chromosomal content and surface markings and charge. these methods also reduce sperm chromatin deficiencies and screen the sperms before applying in assisted reproduction techniques. objective: this study compared simple density gradient methods and a combin...

متن کامل

Effect of combined density gradient centrifugation on X- and Y- sperm separation and chromatin integrity

BACKGROUND It has been claimed that by using different washing methods, the sperms can be separated according to size, motility, density, chromosomal content and surface markings and charge. These methods also reduce sperm chromatin deficiencies and screen the sperms before applying in assisted reproduction techniques. OBJECTIVE This study compared simple density gradient methods and a combin...

متن کامل

Sperm selection using single layer centrifugation prior to cryopreservation can increase thawed sperm quality in stallions.

REASONS FOR PERFORMING STUDY The increasing use of modern reproductive techniques in human medicine has led to a higher demand for isolation of motile sperm. Several of these isolation techniques have been adapted for veterinary use and can be applied for the selection of a superior sperm sample from stallion semen. Until recently a major disadvantage of such isolation techniques was the limita...

متن کامل

Inter-center variation in the efficiency of sperm DNA damage reduction following density gradient centrifugation

This was a prospective multicenter study aiming at comparing the efficiency of sperm selection by density gradient centrifugation (DGC) in reducing sperm DNA fragmentation (SDF) in different ART centers. The study was designed using 290 semen samples collected from 10 different ART centers performing artificial insemination, in vitro fertilization and blind assessment of SDF at the University f...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of reproductive biomedicine

جلد ۷، شماره ۲، صفحات ۷۳-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023