comparison of two dimensional and live three dimensional ultrasounds for the diagnosis of septated uterus

نویسندگان

maryam niknejadi

farnaz akhbari

fatemeh niknejad

gholamreza khalili

چکیده

background:   objective: the objective of the present study was to evaluate the application of two dimensional ultrasound (2-dus) and real time three dimensional ultrasound (3-dus) in differentiating various type of septated uterus. hysteroscopy confirmation was assigned as the gold standard.   materials and methods: this retrospective study was performed among 215 infertile women with suspected septate uterus from october 2008 to july 2012. an inclusion criterion was septated uterus based on hsg or experiencing abortion, preterm labor, or recurrent ivf failure. fusion anomalies were excluded from the study (unicornuate, bicornuate and didelphys anomalies). the results of 3d and 2d sonographies were compared, while they were confirmed by hysteroscopy result in detection of septated uterus. kappa index for agreement between 2dus and hysteroscopy, as well as 3-dus and hysteroscopy in detection of septate uterus was carried out. by receiver operating characteristic (roc) curve, cut off points for predicting the kind of anomalies were proposed. results: the women were evaluated by 2-dus (n=89) and (ii) 3-dus (n=126). all women underwent hysteroscopy, following 2-dus and 3-dus at the same or subsequent cycle. the results of kappa (k) index were 0.575 and 0.291 for 3-dus and hysteroscopy, as well as 2-dus and hysteroscopy, respectively. also, the cutoff points were 27% for arcuate and subseptate, and 35% for differentiating septate and subseptate. conclusion: real time 3-dus has better ability for visualization both uterine cavity and the fundal uterine, so it has higher agreement in detection of septate uterus than 2-dus. traditionally, septate uterus was diagnosed with invasive method like hysterosalpingography and hysteroscopy. nowadays transvaginal ultrasonography was reported to be a sensitive tool for detection of septate uterus too.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of two dimensional and live three dimensional ultrasounds for the diagnosis of septated uterus

BACKGROUND Traditionally, septate uterus was diagnosed with invasive method like hysterosalpingography and hysteroscopy. Nowadays transvaginal ultrasonography was reported to be a sensitive tool for detection of septate uterus too. OBJECTIVE The objective of the present study was to evaluate the application of two dimensional ultrasound (2-DUS) and real time three dimensional ultrasound (3-DU...

متن کامل

Three-Dimensional Image of A Communicating Uterus

Recent advances in reproductive medicine have created a demand for more accurate and safe imaging modalities before assisted reproductive treatment(ART) (1). Gradually, the important role of three-dimensional (3D) ultrasonography in the diagnosis of uterine congenital anomalies has been proved (2-4).

متن کامل

the evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine

abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...

15 صفحه اول

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

a case study of the two translators of the holy quran: tahereh saffarzadeh and laleh bakhtiar

بطورکلی، کتاب های مقدسی همچون قران کریم را خوانندگان میتوان مطابق با پیش زمینه های مختلفی که درند درک کنند. محقق تلاش کرده نقش پیش زمینه اجتماعی-فرهنگی را روی ایدئولوژی های مترجمین زن و در نتیجه تاثیراتش را روی خواندن و ترجمه آیات قرآن کریم بررسی کند و ببیند که آیا تفاوت های واژگانی عمده ای میان این مترجمین وجود دارد یا نه. به این منظور، ترجمه 24 آیه از آیات قرآن کریم مورد بررسی مقایسه ای قرار ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of reproductive biomedicine

جلد ۱۲، شماره ۸، صفحات ۵۴۷-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023