simple and safe packing method for high-grade liver injuries

نویسندگان

mehrdad hosseinpour trauma research center, kashan university of medical sciences, kashan, ir iran; trauma research center, kashan university of medical sciences, kashan, ir iran, tel: +98-3615550026, fax: +98-3615558900سازمان اصلی تایید شده: دانشگاه علوم پزشکی کاشان (kashan university of medical sciences)

mohammad reza asgarzadeh department of surgery, faculty of medicine, isfahan university of medical sciences, isfahan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (isfahan university of medical sciences)

mahdi mohammadzadeh trauma research center, kashan university of medical sciences, kashan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی کاشان (kashan university of medical sciences)

farzad parvizian department of surgery, faculty of medicine, isfahan university of medical sciences, isfahan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (isfahan university of medical sciences)

چکیده

results: patients in the case and control groups were similar in age and admission vital signs. during the second operation, the bleeding volumes measured in the case and control groups were 66 ± 27.01 ml and 152 ± 85.4 ml, respectively. there was some pad-induced damage after the removal of the pad in the control group. patients and methods: twenty male patients with grade iv or v liver injuries that required laparotomy were enrolled in the study. ten patients were treated using conventional packing, while the other 10 were treated using the three-layer pack. in the case group, the liver was mobilized as much as possible. the three-layer pack was then placed at the site of liver damage and extended onto the liver surface, and the other pads were placed on top of this pad. after 72 h, reoperation was performed, the packs were removed, and the packs causing injury were recorded. additionally, if rebleeding due to the adhesive bands of the pack was observed, the blood was suctioned and bleeding volume was measured. data were analyzed using the mann–whitney test. objectives: in this study, opsite sheets were used to make three-layer packs for decreasing the complication associated with removing gauze packing. background: injury to the liver is a commonly encountered problem in trauma cases and is a frequent cause of morbidity and mortality. because gauze packing is easy to use and has the potential for rapid hemorrhage control, it is the most commonly used method for patients with severe liver injuries, particularly those with coagulopathy. conclusions: our study has provided a simple and safe packing method for high-grade liver injuries.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple and Safe Packing Method for High-Grade Liver Injuries

BACKGROUND Injury to the liver is a commonly encountered problem in trauma cases and is a frequent cause of morbidity and mortality. Because gauze packing is easy to use and has the potential for rapid hemorrhage control, it is the most commonly used method for patients with severe liver injuries, particularly those with coagulopathy. OBJECTIVES In this study, OpSite sheets were used to make ...

متن کامل

modified perihepatic packing; a creative and beneficial method for management of high grade liver injury

objective: to evaluate the efficacy of modified perihepatic packing (mphp) in reducing the rate of re-bleeding rate after packing removal. methods: this was an experimental study being performed in shiraz animal laboratory. high grade liver parenchymal injury was induced in 30 transgenic australian rabbits which were then divided into two groups. group a (control) included 14 and group b (exper...

متن کامل

Modified Perihepatic Packing; A Creative and Beneficial Method for Management of High Grade Liver Injury.

OBJECTIVE To evaluate the efficacy of modified perihepatic packing (MPHP) in reducing the rate of re-bleeding rate after packing removal. METHODS This was an experimental study being performed in Shiraz animal laboratory. High grade liver parenchymal injury was induced in 30 transgenic Australian rabbits which were then divided into two groups. Group A (control) included 14 and group B (exper...

متن کامل

A simple and safe method for preparation of Mg(OH)2 nanorods in ambient air

Magnesium hydroxide Mg(OH)2 nanorods with diameters of 90±10nm and lengths of more than 2μms were prepared by a simple route at ~75oC in ambient air. The approach is based on reaction of magnesium powder and de-ionized water without the use of any harmful, toxic or corrosive reagents. Characterization using X-ray diffraction (XRD) shows single crystalline structure of Mg(O...

متن کامل

A simple and safe method for preparation of Mg(OH)2 nanorods in ambient air

Magnesium hydroxide Mg(OH)2 nanorods with diameters of 90±10nm and lengths of more than 2μms were prepared by a simple route at ~75oC in ambient air. The approach is based on reaction of magnesium powder and de-ionized water without the use of any harmful, toxic or corrosive reagents. Characterization using X-ray diffraction (XRD) shows single crystalline structure of Mg(O...

متن کامل

I-4: A Simple and Safe Technique for Varicocele Surgery

s:2127:"Varicocele is the most common pathologic finding in men in infertility study programs and is the most treatable cause of male infertility. Its correction is performed by different surgical techniques, none of which is yet acknowledged as the "gold standard." Some of them, especially the microsurgical ones, are very time consuming and thus expensive; furthermore, all varicocele surgery i...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
archives of trauma research

جلد ۱، شماره ۱، صفحات ۳۱-۳۴

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023