acromioclavicular joint fixation using an acroplate combined with a coracoclavicular screw
نویسندگان
چکیده
background appropriate treatment of acromioclavicular joint dislocation is controversial. acroplate fixation is one of the most common treatment methods of acromioclavicular joint (acj) dislocation. based on the risk of re-dislocation after acroplate fixation, we assumed that combined fixation with an acroplate and a coracoclavicular screw helps improve the outcome. objectives the main purpose of the current study was to compare the outcome of acj dislocation treated with an acroplate alone and in combination with coracoclavicular screw. patients and methods this study was carried out on 40 patients with acj dislocation types iii to vi who were divided randomly into two equal groups: acroplate group (p) and acroplate in combination with coracoclavicular screw group (p + s). the screws were extracted 3-6 months postoperatively. the patients were followed for 1 year and imatani’s score was calculated. finally, the data were compared between the groups. results the mean imatani’s score was significantly higher in p + s group (83.4 ± 14.1) than p group (81.2 ± 10.3) (p < 0.001). the mean duration of surgery was the same in the two groups (59.8 ± 9.4 minutes in group p v.s 64.3 ± 10.9 minutes in group p + s; p = 0.169). there were no cases of re-dislocation, degenerative changes and ossification and all patients returned to their previous jobs or sporting activities. conclusions using a coracoclavicular screw combined with an acroplate can improve the patients’ function after acj disruption without any significant increase in surgical duration. authors recommend this technique in the fixation of acj dislocation.
منابع مشابه
Acromioclavicular Joint Fixation Using an Acroplate Combined With a Coracoclavicular Screw
BACKGROUND Appropriate treatment of acromioclavicular joint dislocation is controversial. Acroplate fixation is one of the most common treatment methods of acromioclavicular joint (ACJ) dislocation. Based on the risk of re-dislocation after Acroplate fixation, we assumed that combined fixation with an Acroplate and a coracoclavicular screw helps improve the outcome. OBJECTIVES The main purpos...
متن کاملComparison of Acute Acromioclavicular Joint Dislocation Treatment by Screw Fixation with and without Ligament Reconstruction
Background & Aims: Acute acromioclavicular (AC) joint dislocation is common in shoulder injuries. Considering the biomechanics of this joint, the use of a treatment method, which can restore joint physiology and biomechanics to the extent possible, is important. This study aimed to compare the treatment of acute AC joint dislocation by screw fixation with and without ligament reconstruction. Me...
متن کاملBioabsorbable screw fixation in coracoclavicular ligament reconstruction.
The purpose of this study is to evaluate the biomechanical properties of stainless steel and bioabsorbable screw fixation of the clavicle to the base of the coracoid. Seven matched pairs of fresh frozen shoulders were prepared by removing all soft tissue except the acromioclavicular and coracoclavicular ligament complexes. The shoulders were randomly selected and fixed with 4.5-mm stainless ste...
متن کاملSurgical treatment of acute complete acromioclavicular dislocation: comparison of coracoclavicular screw fixation supplemented with tension band wiring or ligament transfer.
BACKGROUND Treatment of acute complete acromioclavicular (AC) dislocation is still controversial. Both non-surgical and surgical methods have been reported with similar results. In addition, once surgical treatment is chosen, a satisfactory surgical technique has not been developed yet. METHODS Sixty consecutive patients who sustained 60 acute complete AC dislocations were treated using corac...
متن کاملFunctional coracoclavicular stabilization for acute acromioclavicular joint disruption.
Drs Dimakopoulos and Panagopoulos are from the University Hospital of Patras, Orthopaedic Clinic, Shoulder and Elbow Surgery Unit, Rio-Patras, Greece. Correspondence should be addressed to: Andreas Panagopoulos, MD, Riga Fereou 19, 26504 AktaioRio, Patras, Greece. This article presents a coracoclavicular functional stabilization technique to restore the anteroposterior and vertical displacement...
متن کاملTemporary coracoclavicular screw fixation for displaced distal clavicle fractures.
PURPOSE To assess the treatment outcome of temporary coracoclavicular screw fixation for displaced distal clavicle fractures. METHODS From January 1995 to December 2003, 30 consecutive patients with Neer type II displaced distal clavicle fractures were treated with open reduction and internal fixation using a coracoclavicular screw. The screw was removed under local anaesthesia after bony uni...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
archives of trauma researchجلد ۲، شماره ۱، صفحات ۳۶-۳۹
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023