is a magnetic-manual targeting device an appealing alternative for distal locking of tibial intramedullary nails?

نویسندگان

lukas l. negrin department of trauma surgery, medical university of vienna, vienna, austria; department of trauma surgery, medical university of vienna, vienna, austria. tel: +43-1404005901, fax: +43-1404005939

vilmos vécsei department of trauma surgery, medical university of vienna, vienna, austria

چکیده

conclusions due to our satisfactory test results, the brief training, the steep learning curve and the radiation-free technique the new device has to be considered an appealing alternative for distal locking. objectives our cadaver study was performed to evaluate the accuracy and efficiency of this device. materials and methods in two runs, 30 probands (group 1: 10 students; group 2: 10 residents; group 3: 10 attendings), none of who being familiar with the device, tested the radiation-free system using 60 intact cadaver tibias. each proband performed the surgical procedure twice in succession. results referring to the first attempts, 9.6, 7.2 and 7.1 minutes were the time periods required to insert the four distal screws and the relevant values for the second attempts were 8.6, 6.3 and 6.2 minutes; in both cases revealing a significant difference between group 1 and 2 and group 1 and 3. furthermore, the mean values within each group indicated a significant decrease of the test duration. out of the 240 drillings, only one failure (group 1) occurred, representing an accuracy of 99.58 %. of the probands, 90 % rated the targeting device better than the free-hand technique and 77 % at least attested a high user-friendliness. background in order to enable a radiation-free, accurate and simple positioning of distal locking screws, a combined magnetic and manual targeting system has been developed by sanatmetal®. where a low-frequency magnetic field is initially used to detect the position of the first drill hole and three more holes can be found with a mechanical template.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is a Magnetic-Manual Targeting Device an Appealing Alternative for Distal Locking of Tibial Intramedullary Nails?

BACKGROUND In order to enable a radiation-free, accurate and simple positioning of distal locking screws, a combined magnetic and manual targeting system has been developed by Sanatmetal®. Where a low-frequency magnetic field is initially used to detect the position of the first drill hole and three more holes can be found with a mechanical template. OBJECTIVES Our cadaver study was performed...

متن کامل

The Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures

Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...

متن کامل

Posterior to anterior distal locking of humeral intramedullary nails

TECHNIQUE Humeral nailing is performed with the patient in the lateral decubitus position with the image intensifier at 90o to the patient (Fig 1). During freehand distal locking, the patient’s arm rests on his or her body and the forearm is rested on the anterior pelvic support on sterile padding. By changing the amount of padding, arm rotation can be adjusted to give a perfect view of the dis...

متن کامل

Distal Locking Screws for Intramedullary Nailing of Tibial Fractures.

Recently introduced tibial intramedullary nails allow a number of distal screws to be used to reduce the incidence of malalignment and loss of fixation of distal metaphyseal fractures. However, the number of screws and the type of screw configuration to be used remains obscure. This biomechanical study was performed to address this question. Thirty-six Expert tibial nails (Synthes, Oberdorf, Sw...

متن کامل

Fatigue strength of common tibial intramedullary nail distal locking screws

BACKGROUND Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8-10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery....

متن کامل

Tibial lengthening over intramedullary nails

OBJECTIVES The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. METHODS In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were ret...

متن کامل