tangential view and intraoperative three-dimensional fluoroscopy for the detection of screw-misplacements in volar plating of distal radius fractures

نویسندگان

sascha rausch trauma department, jena university hospital, jena, germany; trauma department, jena university hospital, jena, germany. tel: +49-36419322889, fax: +49-36419322802

ivan marintschev trauma department, jena university hospital, jena, germany

isabel graul trauma department, jena university hospital, jena, germany

arne wilharm trauma department, jena university hospital, jena, germany

چکیده

conclusions we recommend the additional 2d-fluoroscopic tangential view for detection of screw misplacements caused by overlength, with penetration on the dorsal cortical surface of the distal radius, predominantly observed for the most lateral screw position. the use of intraoperative 3d fluoroscopy did not become accepted in our clinical routine, due to the technical demanding and time consuming procedure, with a limited image quality so far. results in the standard 2d-fluoroscopic views (postero-anterior and true lateral projection), 22 screw misplacements of 232 inserted screws were not detected. based on the additional tangential view, 12 screws were exchanged, followed by further 10 screws after performing the 3d fluoroscopic scan. the most lateral screw position had the highest risk for screw misplacement (accounting for 45.5% of all exchanged screws). the mean number of images for the tangential view was 3 ± 2.5 images. the mean surgical time was extended by 10.02 ± 3.82 minutes for the 3d fluoroscopic scan. an additional radiation exposure of 4.4 ± 4.5seconds, with a dose area product of 39.2 ± 14.5 cgy/cm2 were necessary for the tangential view and 54.4 ± 20.9 seconds with a dose area product of 2.1 ± 2.2 cgy/cm2, for the 3d fluoroscopic scan. objectives the following questions should be answered in this study; 1) are the additional tangential view and the intraoperative 3d fluoroscopy useful in the clinical routine to detect persistent fracture dislocations and screw misplacements, to prevent revision surgery? 2) which is the most dangerous plate hole for screw misplacement? patients and methods a total of 48 patients (36 females and 13 males) with 49 unstable distal radius fractures (22 x 23 a; 2 x 23 b, and 25 x 23 c) were treated with a 2.4 mm variable angle lcp two-column volar distal radius plate (synthes gmbh, oberdorf, switzerland) during a 10-month period. after final fixation, according to the manufactures' technique guide and control of implant placement in the two common perpendicular 2d-fluoroscopic images (postero-anterior and true lateral), an additional tangential view and intraoperative 3d fluoroscopic scan were performed to control the anatomic fracture reduction and screw placements. intraoperative revision rates due to screw misplacements (intra-articular or overlength) were evaluated. additionally, the number of surgeons, time and radiation-exposure, for each step of the operating procedure, were recorded. background volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. on the other hand, intra-articular screw misplacements will promote osteoarthritis, while the penetration of the contralateral bone surface may result in tendon irritations and ruptures. the intraoperative control of fracture reduction and implant positioning is limited in the common postero-anterior and true lateral two-dimensional (2d)-fluoroscopic views. therefore, additional 2d-fluoroscopic views in different projections and intraoperative three-dimensional (3d) fluoroscopy were recently reported. nevertheless, their utility has issued controversies.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures

BACKGROUND Volar locking plate fixation has become the gold standard in the treatment of unstable distal radius fractures. Juxta-articular screws should be placed as close as possible to the subchondral zone, in an optimized length to buttress the articular surface and address the contralateral cortical bone. On the other hand, intra-articular screw misplacements will promote osteoarthritis, wh...

متن کامل

The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography.

OBJECTIVES To assess the utility of the dorsal tangential view (DTV) in detecting intraoperative dorsal screw penetration in distal radius fractures treated with volar locked plating. DESIGN Retrospective cohort study. SETTING Academic level 1 trauma center. PATIENTS/PARTICIPANTS Skeletally mature patients where open reduction internal fixation with volar locked plating was the definitive...

متن کامل

Complications of volar plating of distal radius fractures.

Open reduction and internal fixation has been shown to be effective in the treatment of unstable distal radius fractures. When a dorsal approach is used, extensor tendons rupture or irritation are frequent and well known complications. Complications associated with volar plate fixation have not been studied to the same extent. In this study a homogenous series of 90 patients treated by volar pl...

متن کامل

Volar Plating as a Treatment for Distal Radius Fractures

Locked volar plating is the most common surgical procedure to address distal radius fractures. The extended flexor carpi radialis (FCR) approach continues to be an excellent method for visualizing distal radius fractures and applying a volar plate. (See Video 1, Supplemental Digital Content 1, which discusses distal radial fracture advancements and possible complications. This video is availabl...

متن کامل

Volar Angle Stable Plating for Distal Radius Fractures

The treatment of distal radius fractures has evolved substantially over recent years. Most authors still agree that anatomic reconstruction of both the radiocarpal and radioulnar joints is required to restore normal wrist kinematics and achieve optimal outcomes in both the short and long term.1–3 More controversial is the question of how to achieve anatomic reconstruction of the distal radius. ...

متن کامل

Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures

BACKGROUND The dorsal tangential (DT) view has been shown to improve the detection of dorsal screw perforation during volar distal radius fracture fixation. Here we performed a cadaveric imaging survey study to evaluate if the DT view was uniformly beneficial for all screws. METHODS Standardized placement of fixed-angle volar distal radius plates was performed on two cadavers. Fluoroscopic im...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
archives of trauma research

جلد ۴، شماره ۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023