surgical treatment of unstable distal radius fractures with a volar variable-angle locking plate: clinical and radiological outcomes
نویسندگان
چکیده
conclusions the use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. objectives this study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. patients and methods we reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. the mean age of the patients was 32.82 ± 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 ± 2.47 months (range 6 to 15). all of the patients underwent open reduction and internal fixation with a variable-angle locking plate. radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. the functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. gartland and werley’s demerit scoring system was used to assess the final outcome. results there were two cases of superficial infection that responded to oral antibiotics. one patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. there was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. according to gartland and werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. background unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. the use of variable-angle locking plates is promoted for the management of these fractures.
منابع مشابه
Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes
BACKGROUND Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. OBJECTIVES This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. PATIENT...
متن کاملTreatment of unstable distal radius fractures with the volar locking plate
BACKGROUND Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures. PURPOSE To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. PATIENTS AND METHODS A retrospective review was conducted of patients from one instituti...
متن کاملDistal radius volar locking plates: does a variable angle locking system confer a clinical advantage?
This retrospective study compared clinical, radiological and subjective outcomes between patients with a distal radius fracture fixed with a variable angle or fixed angle volar locking plate. Radiological parameters were assessed between initial and final post-operative films. Post-operative clinical range of motion as a proportion of that in the opposite wrist was assessed clinically, and sati...
متن کاملVolar plate fixation of distal radius fractures.
Volar fixed angle fixation may be considered as the beginning of a new era in restoring wrist function to patients with dorsally displaced distal radius fractures even in the face of comminuted or osteopenic bone. A thorough understanding of the anatomy of the wrist is a prerequisite when volarly approaching dorsally displaced distal radius fractures. The demonstration of the device theoretical...
متن کاملComparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures
Distal radius fractures are one of the most common injuries and this incidence is likely to increase as the aging population increases. The type of operation and implant is a matter of discussion and randomized trials and meta analyses have failed to recommend the preferred implant. Internal fixation with volar locking plate and external fixation with supplementation with K wire have been succe...
متن کاملTreatment of unstable distal radius fractures: non-invasive dynamic external fixator versus volar locking plate - functional and radiological outcome in a prospective case-controlled series.
INTRODUCTION Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. AIMS To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate co...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
archives of trauma researchجلد ۵، شماره ۲، صفحات ۰-۰
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023