effects of high versus low flux membranes on o2 saturation in hemodialysis patients

نویسندگان

ali momeni department of internal medicine, shahrekord university of medical sciences, ir iran +98-9133267459, [email protected]; department of internal medicine, shahrekord university of medical sciences, ir iran +98-9133267459, [email protected]

hamid rouhi department of internal medicine, shahrekord university of medical sciences, ir iran +98-9133267459, [email protected]

masoud amiri social health determinants research center and department of epidemiology and biostatistics, school of health, shahrekord university of medical sciences, ir iran

چکیده

background several studies have been carried out to evaluate the effects of dialysis on o2 saturation. while the dialysis procedure may lead to hypoxia under different circumstances, there are few studies available on the effects of membrane type on o2 saturation in these patients. objectives this study was to appraise the effects of high and low flux membrane on pulse oxymetery in dialysis patients. patients and methods in a cross-sectional evaluation, 43 hemodialysis patients without pulmonary disease were enrolled. of this group, dialysis was performed by low and high flux membranes, and pulse oxymetery was applied before and after the procedures. results mean age of the patients was 56.34 years. of these patients, 23 (53.5%) and 20 (46.5%) were women and men, respectively. type of membrane (high flux vs. low flux) did not show any significant effect on pulse oxymetery results (p > 0.05). conclusions due to the lack of a significant difference in pulse oxymetery and creation of hypoxia between two types of membranes in hemodialysis patients, as well as the high cost of high flux membrane as compared to the low flux membrane, we do not suggest the use of high flux membrane in dialysis.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of High Versus Low Flux Membranes on O2 Saturation in Hemodialysis Patients

BACKGROUND Several studies have been carried out to evaluate the effects of dialysis on O2 saturation. While the dialysis procedure may lead to hypoxia under different circumstances, there are few studies available on the effects of membrane type on O2 saturation in these patients. OBJECTIVES This study was to appraise the effects of high and low flux membrane on pulse oxymetery in dialysis p...

متن کامل

Effects of High-Flux versus Low-Flux Membranes on Pulmonary Function Tests in Hemodialysis Patients

BACKGROUND Several studies have been carried out to evaluate the effects of dialysis on pulmonary function tests (PFT). Dialysis procedure may reduce lung volumes and capacities or cause hypoxia; however, to the best of our knowledge, there is no previous study evaluating the effects of membrane type (high flux vs. low flux) on PFT in these patients. The aim of this study was the evaluation of ...

متن کامل

high-flux and low-flux membranes: efficacy in hemodialysis

results the mean kt/v was 1.27 ± 0.28 in high-flux and 1.10 ± 0.32 in low-flux membrane which, these differences were statistically significant (p = 0.017). the mean of urr was 0.65 ± 0.09 in high-flux and 0.61 ± 0.14 in low-flux membrane, which these differences were not statistically significant (p = 0.221). patients and methods forty hemodialysis patients participated in this cross-over clin...

متن کامل

High-Flux and Low-Flux Membranes in Hemodialysis

Background: Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that highflux membrane improves removal of moderatemolecules while other studies no significant on them. Objectives: The aim of this study was to investigate the dialysis adequacy of low-flux versus high-flux membranes in Hemodialysis Patients. Patients and Methods: Forty ...

متن کامل

High-Flux and Low-Flux Membranes: Efficacy in Hemodialysis

BACKGROUND Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that high-flux membrane improves the removal of moderate-sized molecules while other studies indicate no significant effect on them. OBJECTIVES This study aimed to investigate the dialysis efficacy of low-flux versus high-flux membranes in hemodialysis patients. PATIENT...

متن کامل

Pyrogen transfer across high- and low-flux hemodialysis membranes.

The extent to which bacterial products from contaminated dialysate enter a patient's blood depends upon the type and permeability of the hemodialysis membrane in use. This study was performed to assess the transfer of pyrogenic substances across both high- and low-flux membranes (DIAPES, Fresenius Polysulfone, Helixone, Polyamide S). All experiments were carried out in the saline-saline model. ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
nephro-urology monthly

جلد ۵، شماره ۱، صفحات ۶۸۳-۶۸۶

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023