increasing the reliability of the grading system for voiding cystourethrograms using ultrasonography: an inter-rater comparison

نویسندگان

seyithan ozaydin department of pediatric surgery, kanuni sultan suleyman education and research hospital, istanbul, turkey; department of pediatric surgery, kanuni sultan suleyman education and research hospital, istanbul, turkey. tel: +05-057456577, fax: +090-2162453693

suleyman celebi department of pediatric surgery, kanuni sultan suleyman education and research hospital, istanbul, turkey

ismail caymaz department of pediatric radiology, faculty of medicine, baskent university, istanbul, turkey

cemile besik department of pediatric surgery, kanuni sultan suleyman education and research hospital, istanbul, turkey

چکیده

conclusions inter-rater accuracy could be improved at middle grades using renal ultrasonography (usg), which could promote communication between different specialists. results the intraclass correlation coefficient (icc) values ranging from 0.86 to 0.89 reflected good reliability. the lowest agreement was associated with middle grades (iii and iv). a marked difference in sensitivity was observed between groups 1 and 3 (35% and 95%, respectively, p < 0.05), indexed by sfu hydronephrosis grade, suggesting that vcug cases in group 2 (n = 16 at sfu 0 or 1) could be accepted as grade iii, and sfu scores of 2, 3, or 4 could be considered grade iv. objectives therefore, this study assessed the accuracy of the current vcug staging system by assessing inter-rater reliability among pediatric radiologists and urologists; it also evaluated whether accuracy is increased by ru without consensus (with respect to vcug grading). methods four pediatric urologists and four pediatric radiologists independently graded 120 voiding cystourethrograms (vcugs). middle vur grades were divided into the following three groups: vur consensus grade iii (group 1), vur consensus grade iv (group 3), and vur non-consensus grades iii and iv (group 2). all groups were compared with respect to hydronephrosis grade using ru. background to assess the effectiveness of the current vesicoureteral reflux (vur) grading system according to the international classification of vur (icvur) and to evaluate whether vur grading accuracy could be improved by renal ultrasonography (ru) according to the society for fetal urology (sfu) grading system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Increasing the Reliability of the Grading System for Voiding Cystourethrograms Using Ultrasonography: An Inter-Rater Comparison

BACKGROUND To assess the effectiveness of the current vesicoureteral reflux (VUR) grading system according to the international classification of VUR (ICVUR) and to evaluate whether VUR grading accuracy could be improved by renal ultrasonography (RU) according to the Society for Fetal Urology (SFU) grading system. OBJECTIVES Therefore, this study assessed the accuracy of the current VCUG stag...

متن کامل

the use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach

abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...

15 صفحه اول

Ultrasound assessment for grading structural tendon changes in supraspinatus tendinopathy: an inter-rater reliability study

AIM To evaluate the inter-rater reliability of measuring structural changes in the tendon of patients, clinically diagnosed with supraspinatus tendinopathy (cases) and healthy participants (controls), on ultrasound (US) images captured by standardised procedures. METHODS A total of 40 participants (24 patients) were included for assessing inter-rater reliability of measurements of fibrillar d...

متن کامل

Inter-rater reliability study of the modified Oxford Grading Scale and the Peritron manometer.

OBJECTIVE To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. DESIGN All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. PARTICIPANTS Nineteen women with a mean age of 23.7 years (range 21 to 28...

متن کامل

Computing Inter-Rater Reliability With the SAS System

The SAS system V.8 implements the computation of unweighted and weighted kappa statistics as an option in the FREQ procedure. A major limitation of this implementation is that the kappa statistic can only be evaluated when the number of raters is limited to 2. Extensions to the case of multiple raters due to Fleiss (1971) have not been implemented in the SAS system. A SAS macro called MAGREE.SA...

متن کامل

Inter-Rater Reliability of the CASCADE Criteria

See related article, p 2439. Childhood arterial ischemic stroke (AIS) has received increasing attention as a cause of morbidity and mortality in the pediatric population. Several population-based studies in the United States demonstrate an incidence of childhood AIS at 2 cases per 100 000 children per year, with an incidence in other studies from Asia and Europe ranging from 0.2 to 7.9 per 100 ...