development of an accident reproduction simulator system using a hemodialysis extracorporeal circulation system

نویسندگان

yoshiaki nishite department of biomedical engineering, faculty of biology-oriented science and technology, kinki university, wakayama, japan; department of biomedical engineering, faculty of biology-oriented science and technology, kinki university, wakayama, japan. tel: +81-736773888, fax: +81-736774754

shingo takesawa department of medical engineering, kyushu university of health and welfare clinical engineering, nobeoka, japan

چکیده

conclusions thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training. results the results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. the time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. all alarms were set off in under 20 seconds. background accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. an alarm that corresponds to such accidents can be utilized in the simulation model. objectives the aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. materials and methods in order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. the method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. this was tested on five main models from four dialyzer manufacturers that are currently used in japan.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Accident Reproduction Simulator System Using a Hemodialysis Extracorporeal Circulation System.

BACKGROUND Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. OBJECTIVES The aim of this study was to create an ex...

متن کامل

Malfunction of the extracorporeal circulation system: case report.

BACKGROUND AND OBJECTIVES The introduction of extracorporeal circulation in clinical practice was decisive for the development of modern cardiovascular surgery. Addition of new procedures and equipment, however, brings inherent risks and complications. The objective of this report is to describe a malfunction of the oxygenation system and emphasize the importance of the interaction among the me...

متن کامل

Changes in the fibrinolytic system components during extracorporeal circulation.

In 1954 Gibbon, after many years of experimental work, achieved the first successful total body perfusion in a human patient using a form of cardiopulmonary bypass. A prime aim of all workers in this field since then has been to produce safe and adequate anticoagulation of the blood during such a procedure, and to reverse it swiftly and safely at the end of the operation. Furthermore it seems a...

متن کامل

[Coronary artery bypass surgery using the mini-extracorporeal circulation system: a Spanish unit's experience].

INTRODUCTION AND OBJECTIVES The increasing use of percutaneous interventions has resulted in a significant reduction in coronary artery bypass grafting. Today, patients referred for surgery are older, have more comorbidities, and have undergone previous percutaneous intervention, and their ventricular function is poorer. As a result, surgery has attempted to improve its results by adopting a nu...

متن کامل

Mobile communications system simulator development using structured analysis

In this paper, Structured Analysis (SA) is employed in mobile communications system simulation software development. Programming via SA provides a well-defined and easily maintainable structure for the software in a graphical form, also revealing any hidden dependencies in the software. Thus, the resulting simulator is more reliable and maintainable over its whole lifecycle. With modern SA tool...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
nephro-urology monthly

جلد ۸، شماره ۱، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023