validity of selected wbc differentiation flags in sysmex xt-1800i

نویسندگان

parya bameni moghaddam

dept. of pathology, tehran university of medical sciences, tehran. iran fatemeh mahjoub

dept. of pathology, tehran university of medical sciences, tehran. iran amirhossein emami

dept. of internal medicine, tehran university of medical sciences, tehran, iran alireza abdollahi

dept. of pathology ,imam hospital complex, tehran university of medical sciences, tehran, iran

چکیده

background: automatic cell counter devises make the cbc differential very easy and delivering the results in few second. however, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. in this study, we calculated the validity of wbc diff flags in sysmex xt-1800i. in addition, we verified the correlation between manual and automated samples. methods: overall, 1095 flagged samples were selected in the period of 6 weeks (imam hospital complex, tehran iran, 2014). the results of both automated and manual counting of the samples were carefully studied and compared. totally, 624 nrbc flags, 450 blast flags, 155 abnormal wbc scatter gram flags, 140 eosinophilia flags and 468 monocytosis flags were identified. results: considering nrbc and blast flags there was a significant difference between our manual counted and automated counted nrbcs and blasts (p

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity of Selected WBC Differentiation Flags in Sysmex XT-1800i

Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...

متن کامل

Performance characteristics of the Sysmex XT-2000i hematology analyzer.

The XT-2000i is a new hematology analyzer combining aperture impedance and optical technologies. It is capable of generating a 30-parameter hematologic assay on peripheral blood at a throughput of 80 samples per hour. We have evaluated the performance characteristics of the XT-2000i analyzer and compared them with those of the state-of-the-art XE-2100 analyzer and the manual differential count....

متن کامل

Optimized gating and reference ranges of reticulated platelets in dogs for the Sysmex XT-2000iV

BACKGROUND Canine reticulated platelets (r-PLTs) i.e., juvenile PLTs reflecting thrombopoiesis can be measured automatically with the hematology analyzer Sysmex XT-2000iV using manual gating options. However, the impact of interferences on r-PLT measurements performed with the gates published previously (Pankraz et al., Vet Clin Path 38:30-38, 2009; Gelain et al., High fluorescent platelets fra...

متن کامل

The performance of BD FACSPresto™ for CD4 T-cell count, CD4% and hemoglobin concentration test in Ethiopia

INTRODUCTION In Ethiopia, CD4+ T-cell counting is still required for all patients at baseline before antiretroviral therapy (ART) and to determine eligibility and follow-up of opportunistic infection prophylaxis. However, access to CD4+ T cell count in rural health facilities remains a major challenge in Ethiopia like other resource-limited settings. METHODOLOGY Both capillary and venous bloo...

متن کامل

Evaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte

Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...

متن کامل

Biochemical characterization of the adhesion-related differentiation antigen XT-1.

The XT-1-molecule, an adhesion-related differentiation antigen of male mouse germ cells, is a 34 000 Mr glycoprotein with major charge isomer at pI 5.1 and is an integral component of the cell membrane. On large late pachytene spermatocyte, the molecule is present at a concentration of 2.5 X 10(3) molecules micron-2, which approximates HLA/ABC concentration on lymphocytes. By comparing the reac...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of pathology

جلد ۱۱، شماره ۲، صفحات ۹۷-۱۰۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023