effective factors on determination of hexavalent chromium in air
نویسندگان
چکیده
introduction: in electroplating processes, hexavalent chromium mist is emitted in air. hexavalent chromium mist can cause lung cancer and nasal septum in workers. as permissible exposure limit (pel) of hexavalent chromium is low (0.5 µg/m 3 ) and it is used in various industries, evaluation of workers exposure to hexavalent chromium is very important. however, hexavalent chromium is relatively unstable and it can be reduced to trivalent chromium during sampling, storage, and extraction. so, factors influencing determination of cr (vi) must be evaluated. in this study, influence of some factors such as sampling time, storage time, type of filter, and storage temperature on reduction of cr (vi) were investigated. materials and methods: in this study, based on experimental design, 168 hexavalent chromium mist samples were collected and analyzed according to the niosh 7600 method. all samples were collected by two types of filters (pvc, bqff) at different sampling durations (30, 180, 480 min) and different storage times (0, 3, 24, 72 hours). some samples were analyzed immediately after sampling and some of them were stored at 3, 24, and 72 hours at two different temperatures (20-25 °c , 4 °c ). results: results showed that, cr (vi) concentration was decreased with increasing the sampling time (p value <0.001), also, cr (vi) concentration was decreased gradually with increasing of storage duration (p value < 0.001). hexavalent chromium mean concentration in bqff filter was more than pvc filter (p value <0.001). also, storage temperatures had no effect on reduction of cr (vi) (p value >0.05) conclusion : because of acidic and instability of cr (vi) mist air, by increasing sampling time, cr (vi) is reduced. also, acidic media of filter at sample storage can cause possible reaction of polymeric and oligomer materials of filter media with cr (vi), in which, with increasing storage time, cr (vi) can be reduced on filters. on the whole, at starting sampling times (30 min) bqff is more efficient than pvc for collection of cr (vi). based on the obtained results, storage conditions of samples had no effect on cr (vi) reduction.
منابع مشابه
Field method for the determination of insoluble or total hexavalent chromium in workplace air.
National Institute for Occupational Safety and Health method 7703 is a portable field procedure for the analysis of workplace air filter samples for hexavalent chromium (CrVI) content immediately after the samples are collected. The field method prescribes CrVI extraction from air filter samples with an ammonium sulfate/ammonium hydroxide extraction buffer using ultrasonic extraction (UE). Stro...
متن کاملDetermination of Hexavalent Chromium in Drinking Water Using Ion Chromatography
INTRODUCTION Hexavalent chromium, Cr(VI), is the most toxic form of the metal chromium, a primary drinking water contaminant in the U.S. Dissolved hexavalent chromium can be determined as chromate (CrO 4 ) by ion chromatography in drinking water, groundwater, and industrial wastewater effluents as described in U.S. EPA Method 218.6 and Dionex Technical Note 26. Dionex Technical Note 26 uses a 2...
متن کاملDetermination of hexavalent chromium in aqueous and alkaline soil extracts
A fast, simple, and reliable method for determination of hexavalent chromium species in soil aqueous and alkaline extracts has been developed. The procedure is based on the ion-pair extraction of Cr(VI) with methyltrioctylammonium chloride (Aliquat 336) into xylene. The extract is analyzed by flame (FAAS) or electrothermal atomic absorption spectrometry (ETAAS). The method allows the detection ...
متن کاملCarcinogenicity of hexavalent chromium.
Hexavalent chromium (Cr(VI)), a commonly used industrial metal, is a well known human lung carcinogen. Epidemiology and animal studies suggest that the particulate Cr(VI) compounds, specifically the water insoluble compounds, are the more potent carcinogens; however, the carcinogenic mechanism remains unknown. Here we summarize recent Cr(VI)-induced human tumour, in vivo, cell culture and in vi...
متن کاملan investigation on influencing factors on tourists shopping attitude of iranian handmade carpet in isfahan
چکیده ندارد.
15 صفحه اولMicrobial Reduction of Hexavalent Chromium
Publication 1. A. Manceau et al, “Quantitative Zn speciation in smelter-contaminated soils by EXAFS spectroscopy,” Am. J. Sci. (in press, 2000). Figure 3 (top) Soil samples were taken at several depths from a contaminated site. (bottom) Model compounds derived from polarized-EXAFS data at the ESRF and μ-EXAFS data at the ALS provide a good fit with powder-EXAFS spectra from a soil sample, there...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
مجله دانشگاه علوم پزشکی کرمانشاهجلد ۱۲، شماره ۱، صفحات ۰-۰
میزبانی شده توسط پلتفرم ابری doprax.com