optimization of solid phase extraction for trace determination of cobalt (ii) using chromosorb 102 in biological monitoring
نویسندگان
چکیده
cobalt is widely used in different industrial processes for production of various synthetic materials. for assessment of human exposure to toxic metal of co (ii), environmental and biological monitoring are essential processes, in which, preparation of samples is one of the most time-consuming and error-prone aspects prior to instrumental analysis. the aim of this study was to achieve optimum factors necessary for development of a sample preparation technique for cobalt (ii), present in urine, hair, and nail samples followed by atomic absorption spectrometry. solid phase extraction (spe) using mini columns filled with chromosorb 102 resin was optimized regarding sample ph, ligand concentration, loading flow rate, elution solvent, sample volume (up to 500 ml), elution volume, amount of resins, and sample matrix interferences. cobalt ion was retained on sorbent and was eluted with 2 m hno 3 followed by determination by flame atomic absorption spectrometry. obtained recoveries of cobalt ion were more than 92%. to evaluate occupational exposure to co (ii), successful applicability of the optimized method for human exposure was used by treatment real samples, including urine, hair, and nail. suitable results were obtained for relative standard deviation (less than 10%). this optimized method can be considered successful in simplifying sample preparation for trace residue analysis of co (ii) in different matrices when an evaluation of occupational and environmental exposures is required.
منابع مشابه
Review of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملN-octyl-modified magnetite NPs for optimization of solid phase extraction for trace analysis of phenytoin in real samples
objective: Phenytoin is an anti-seizure medication used to treat epilepsy, as well as to control arrhythmias (irregular heartbeat) and to treat migraine headaches and nerve pain. It is recommended to determine the amount of this drug in the blood to control the seizure and prevent its toxicity. In the present study, a sensitive and simple procedure based on the dispersive solid phase extraction...
متن کاملSpectrophotometric Determination of Mefenamic Acid in Biological Samples Using Magnetic Iron Oxide Nanoparticles as a Sorbent for Solid Phase Extraction
This work investigates the potential of magnetic Fe3O4 nanoparticles as an adsorbent for separation and preconcentration of trace amounts of mefenamic acid in aquatic and biological samples, prior to spectrophotometric determination. The magnetic iron oxide nanoparticles (MIONs) were synthesized by mixing of ferrous and ferric chlorides. The possible parameters affecting the enrichment were opt...
متن کاملSolid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy
Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...
متن کاملSolid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy
Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
international journal of occupational hygieneجلد ۲، شماره ۱، صفحات ۱۰-۱۶
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023