feasibility of substituting ethylene with sulfur hexafluoride as a tracer gas in hood performance test by ashrae-110-95 method

نویسندگان

mohammadjavad jafari department of occupational health engineering, school of health, shahid beheshti university of medical sciences, tehran, iran.

saba kalantari department of occupational health engineering, school of health, shahid beheshti university of medical sciences, tehran, iran.

rezvan zendehdel department of occupational health engineering, school of health, shahid beheshti university of medical sciences, tehran, iran.

parvin sarbakhsh department. of statistics and epidemiology, school of public health, tabriz university of medical sciences, tabriz, iran.

چکیده

ansi/ashrae 110-95 protocol is a widely acceptable method to assess the performance of laboratory hoods. in this test, sulfur hexafluoride (sf6) is applied as a tracer gas to quantitatively evaluate the performance of laboratory hoods. the environmentally hostile characteristics of sf6 as well as its cost are the major concerns. in the present study, the substitution of ethylene with sf6 in the ashrae 110-95 test method was investigated. both sf6 and ethylene were applied to a laboratory hood at different face velocities and injection flow rates according to the ashrae 110-95 method. meanwhile, the exposure of a mannequin stationed at the front of hood was measured. the concentration of tracer gases was measured using direct reading instruments. linear regression of the results was used to consider the substitution of ethylene with sf6.the occupational exposure of the proposed hood operator to sf6 and ethylene were 4.2-7.3 ppm and 0.1 to 0.57 ppm respectively. sf6 exposure was increased significantly ( p <0.001) by increasing the injected level while ethylene exposure was decreased significantly ( p <0.001). the linear correlation between the leakage levels of two tracer gases at the injected flow rate of 4 lit/min did not fit well with experimental data. ethylene is not recommended as a substitution for sf6 in ashrae 110-95 hood performance test.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the possibility of applying less tracer gas in ashrae-110-95 method of hood performance test

background and objective : a considerable amount of sulfur hexafluoride is applied to evaluate the performance of each laboratory hood according to ashrae–110-95 method. sf 6 is extremely hostile to environment and expensive. in present work, the possibility of conducting this method of hood performance test with less volume of sf 6 was investigated. material and methods : the performance of a ...

متن کامل

Nitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.

ANSI/ASHRAE Standard 110 provides a quantitative method for testing the performance of laboratory fume hoods. Through release of a known quantity (4.0 Lpm) of a tracer gas, and subsequent monitoring of the tracer gas concentration in the "breathing zone" of a mannequin positioned in front of the hood, this method allows for evaluation of laboratory hood performance. Standard 110 specifies sulfu...

متن کامل

Tracer gas experiments in subways using an integrated measuring and analysis system for sulfur hexafluoride

Abstract. Several sulfur hexafluoride (SF6) tracer gas experiments were conducted in a subway system to measure the possible pathways of toxic gas for subway tunnels and stations empirically. A new mobile integrated measuring and analysis system was used to achieve high sample rates and a long measurement time. Due to the mobility of the sensors, tracer gas experiments were also carried out ins...

متن کامل

Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics.

In order to avoid the inherent aerodynamic difficulties of the conventional fume hood, an innovative design--the 'air curtain-isolated fume hood' is developed. The new hood applies a specially designed air curtain (which is generated by a narrow planar jet and a suction slot flow at low velocities) across the sash plane. The hood constructed for the study is full size and transparent for flow v...

متن کامل

ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد  ASHRAE 110  در

Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...

متن کامل

A Life Cycle Impact Assessment Study on Sulfur Hexafluoride (SF6) as a Gas Insulator

A lifecycle environmental impact analysis was conducted for SF6 used as an insulating gas in electrical devices. Eight scenarios with different forms of usage as an insulating gas (pure SF6 and gaseous mixture of SF6 with nitrogen) and treatment processes of waste SF6 (e.g., reproduction after decomposition, reuse after purification) are assumed. Energy consumption and emission of pollutants an...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of occupational hygiene

جلد ۶، شماره ۱، صفحات ۳۱-۳۶

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023