development and validation of a high-performance liquid chromatography method with uv detection for determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) biuret in rat plasma
نویسندگان
چکیده
results under the above chromatography condition, biuret compound (peqb) and the internal standard were detected at 4.5 and 13.5 minutes, respectively. limit of quantitation of the peqb was 0.1 µg/ml. accuracy of the method over the concentration range of 0.1-100 µg/ml was between 88-109%. inter- and intraday precisions were 4-19% and 6-8%, respectively. a good relationship in the form of a power model was found for two separate concentration ranges of 0.1-1 and 2.5-100 µg/ml (r 2> 0.99). background recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. in this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (peqb) in rat plasma to use in future studies on this compound and related derivatives. objectives in this study, we describe a simple and sensitive high-performance liquid chromatography method with uv detection for determination of 1-(2-phenylethyl)-6-(quinaldin-4-yl) biuret (peqb) in rat plasma. materials and methods separations were performed on a nucleosil-100 cn hplc column (125 × 4.0 mm) (5 µm), using a mixture of acetonitrile: methanol: potassium dihydrogen phosphate buffer (0.05 m, ph 3.5) (10:10:80) as mobile phase delivered at a flow rate of 1 ml/minute. detection of peqb and internal standard (1-([[3-(1,3-benzothiazol-2-ylsulfanyl)propyl]carbamoyl]amino)-n-phenylformamide) was performed at 235 nm and ambient temperature. plasma samples (200 µl) were prepared by addition of 40 µl internal standard (100 µg/ml), and 400 µl acetonitrile. after vortex mixing and centrifugation at 10000 g, 50 µl of the clear supernatant was directly injected onto the chromatography column. calibration curves were constructed by fitting the peak area ratio of the biuret to internal standard against concentration of biuret to a power model using generalized least squares nonlinear regression method. conclusions the presented simple hplc method is sufficiently accurate, precise and sensitive for the quantitation of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret in rat plasma.
منابع مشابه
Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma
BACKGROUND Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plasma to use in future studies on this compound and related derivatives. OBJECTIVES In this study, ...
متن کاملhigh-performance liquid chromatography method for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (a potential cytotoxic agent) in rat plasma
متن کامل
Simultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection
Therapeutic Drug Monitoring (TDM) of first-line anti-tuberculosis (TB) drugs is a decisive tool, allowing the clinician to successfully treat TB patients. The objective of the study was to develop and optimize a simple, sensitive, and reliable high-performance liquid chromatography (HPLC) method for the simultaneous determination of isoniazid (INH), pyrazinamide (PZA), and rifampin (RIF) levels...
متن کاملSimultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection
Therapeutic Drug Monitoring (TDM) of first-line anti-tuberculosis (TB) drugs is a decisive tool, allowing the clinician to successfully treat TB patients. The objective of the study was to develop and optimize a simple, sensitive, and reliable high-performance liquid chromatography (HPLC) method for the simultaneous determination of isoniazid (INH), pyrazinamide (PZA), and rifampin (RIF) levels...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
jundishapur journal of natural pharmaceutical productsجلد ۸، شماره ۲، صفحات ۸۱-۸۵
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023