an invitro study on the temperature changes of dentin, irradiated by co2 and er: cr;ysgg laser

نویسندگان

mohammad asnaashari iranian center for endodontic research , school of dentistry , shahid beheshti university of medical sciences, tehran, iran

reza fekrazad periodontics department, dental school, aja university of medical sciences, tehran, iran

mohammad ali mozayeni iranian center for endodontic research , school of dentistry , shahid beheshti university of medical sciences, tehran, iran

maryam mozayeni iranian center for endodontic research , school of dentistry , shahid beheshti university of medical sciences, tehran, iran

چکیده

introduction:  the aim of this in-vitro study was the evaluation of mperature changes due to irradiation of two different lasers used for the reduction of dentinal hypersensitivity and their effect on the pulp damage. the study was done for two dentin thicknesses.  methods:  twenty intact extracted third molars were prepared by longitudinal ground sectioning for 1 and 2 mm dentin thicknesses while a thermocouple was positioned at the inner surface of the dentin disk. thermal evaluation was assessed by a kjt digital thermometer. during the test, the data produced by the thermometer was transferred and logged into a pc via rs232 serial port. co2 laser (ultra pulse,50w, 100?sec, spot size: 0.5 mm) and er,cr;ysgg laser (free-running pulse mode,0.25w, 140?sec, 12.50 milli-joules) irradiations were randomly performed upon the dentin surfaces. the collected data was analyzed by two-way anova test. results:  the mean temperature rise in 1mm dentinal thickness was 8.57°c which was significantly higher than 3.63°c in 2mm dentin thickness (p<0.001) and higher than the threshold temperature for pulp damage; however, no significant difference was noted between the two lasers (p=0.355). after removing the co2 laser, the temperature decreased to the initial level faster than the time needed for er,cr;ysgg laser (44.47°cversus 62.82°c)(p<0.001). in other words, in both lasers the temperature decrease in 2mm dentinal disc was faster than 1mm dentinal disc. conclusion :    the temperature rise due to both lasers for 1mm of dentinal thickness was in excess of safe limit for the tissue and it would probably result in pulpal damage.in the case of 2mm dentinal thickness, the temperature rise was not higher than the safe limit and it would not damage the pulp in clinical conditions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

XPS analysis of the dentin irradiated by Er: YAG laser.

The aim of this study was to investigate the effect of Er:YAG laser irradiation on human dentin surface using X-ray photoelectron spectroscopy (XPS). 10 human dentin disks were prepared from extracted human molars for XPS analysis. These specimens were divided into two groups of five: a control group and group that were irradiated by an Er:YAG laser beam (100 mJ, 1Hz). All specimens were analyz...

متن کامل

A study on acquired acid resistance of enamel and dentin irradiated by Er,Cr:YSGG laser.

OBJECTIVE This investigation was performed to evaluate the acid resistance of lased enamel and dentin by Er,Cr:YSGG laser to artificial caries-like lesions by spectrophotometry, and the ultrastructure of lased areas was investigated by scanning electron microscopy (SEM) in vitro. BACKGROUND DATA In recent years, many studies have been performed to evaluate the effects of Er,Cr:YSGG laser on d...

متن کامل

study the effects of low level laser diode on no production and healing of diabetic and cortisone acetate and normal wounded sd rats

nitric oxide (no) is a small molecule synthesized by most of mammalian cells with diverse biological activities including vasodilatation, host defense and wound healing. impaired wound healing is a common occurrence among diabetics and patients receiving glucocorticoid therapy. on the other hand the application of laser in biomedical area have been increased. thus, the current studies were desi...

15 صفحه اول

control of the optical properties of nanoparticles by laser fields

در این پایان نامه، درهمتنیدگی بین یک سیستم نقطه کوانتومی دوگانه(مولکول نقطه کوانتومی) و میدان مورد مطالعه قرار گرفته است. از آنتروپی ون نیومن به عنوان ابزاری برای بررسی درهمتنیدگی بین اتم و میدان استفاده شده و تاثیر پارامترهای مختلف، نظیر تونل زنی(که توسط تغییر ولتاژ ایجاد می شود)، شدت میدان و نسبت دو گسیل خودبخودی بر رفتار درجه درهمتنیدگی سیستم بررسی شده اشت.با تغییر هر یک از این پارامترها، در...

15 صفحه اول

Morphological changes of bovine mandibular bone irradiated by Er,Cr:YSGG laser: an in vitro study.

OBJECTIVE The purpose of this study was to investigate the morphological changes of bovine mandibular bone following Er,Cr:YSGG laser irradiation in different methods in vitro. BACKGROUND DATA Recently, an erbium, chromium/yttrium, scandium, garmet (Er,Cr:YSGG) laser device that emits a laser beam at the wavelength of 2.78 micro m was introduced. This type of infrared laser proved to ablate d...

متن کامل

an investigation about the relationship between insurance lines and economic growth; the case study of iran

مطالعات قبلی بازار بیمه را به صورت کلی در نظر می گرفتند اما در این مطالعه صنعت بیمه به عنوان متغیر مستفل به بیمه های زندگی و غیر زندگی شکسته شده و هم چنین بیمه های زندگی به رشته های مختلف بیمه ای که در بازار بیمه ایران سهم قابل توجهی دارند تقسیم میشود. با استفاده از روشهای اقتصاد سنجی داده های برای دوره های 48-89 از مراکز ملی داده جمع آوری شد سپس با تخمین مدل خود بازگشتی برداری همراه با تعدادی ...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of lasers in medical sciences

جلد ۱، شماره ۱، صفحات ۱-۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023